• 11 •
14. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The charger will not
turn on when properly
connected.
AC outlet is dead.
Poor electrical connection.
The quick-connect inline
fuse may be blown.
Reversing the connections
at the battery will cause this.
Check for open fuse or circuit
breaker supplying AC outlet.
Check power cord and
extension cord for loose
fitting plug.
Check the fuse. If it is
blown, replace it with one
of the same size and rating
(2A/32V).
I cannot select a 6V or
12V setting.
The charger is equipped
with Auto Voltage Detection,
which automatically detects
the voltage and charges the
battery.
No problem; this is normal.
CHARGING (yellow/
orange) LED is flashing.
The charger is in abort
mode.
See “Aborted Charge” in
Operating Instructions.
15. SPECIFICATIONS
Input Voltage ..................................................................120V AC @ 60Hz, 0.4A
Output Voltage .......................................6V or 12V, with Auto Voltage Detection
Output Current Rating ................................................ 1A @ 6V DC and 12V DC
16. REPLACEMENT PARTS
Battery clamp cable assembly ......................................................3899002668Z
Ring terminal cable assembly .......................................................2299002276Z