background image

OWNER’S MANUAL

Power Inverter PID-760

Converts DC Battery Power to  

AC Household Power

Includes Clamp Adapter with Cables

00-99-000668/0806

CAUTION:

Read all Safety Rules and Operating Instructions, 

and follow them with each use of this product.

Schumacher Electric Corporation

Mount Prospect, IL 60056 U.S.A.

Send Warranty Product Repairs to:

Customer Service Returns

P.O. Box 280, 1025 E. Thompson

Hoopeston, IL  60942-0280

Questions? Call Customer Service: 1-800-621-5485

Summary of Contents for PID-760

Page 1: ...668 0806 CAUTION Read all Safety Rules and Operating Instructions and follow them with each use of this product Schumacher Electric Corporation Mount Prospect IL 60056 U S A Send Warranty Product Repa...

Page 2: ...the inverter to come into contact with rain or moisture DONOToperatetheinverterifyou theinverter thedevice being operated or any other surfaces that may come in contact with any power source are wet W...

Page 3: ...PID 760 Power Inverter It is important to know the continuous wattage of the device you plan to use with the inverter The PID 760 must be used with devices drawing 760 watts or less If the wattage is...

Page 4: ...ghten so the wire is firmly attached Repeat the same process for the black wire 3 Connect the red positive battery cable to the positive battery terminal taking care to shield eyes clothing and hands...

Page 5: ...power than the inverter is capable of providing POWER SOURCE Your average automobile or marine battery at full charge will provide an ample power supply to the inverter for ap proximately 3 hours whe...

Page 6: ...ts LED DISPLAY The LED readouts identify the current status of the PID 760 VOLTAGE IN Voltage of vehicle s battery or Portable Power jump starter DC power source VOLTAGE OUT Voltage supplied to device...

Page 7: ...tart after the voltage drops below 15 5 volts hip The continuous load demand from the device exceeds 760 watts HoT Inverter is overheated and automatically turns off for a period of 1 3 minutes to coo...

Page 8: ...p m CST 2 Display shows Lob 12 Volt battery too low Recharge replace low battery 3 Display shows Voltage In between 10 5 and 11 0 Volts 12 Volt battery is low Recharge replace low battery Inverter wi...

Page 9: ...device Inverter will automatically reset after cooling PROBLEM Inverter Does Not Turn On Reason Solution 1 Poor contact at terminals Unplug and reinsert PID 760 2 Fuse is blown A blown fuse is usuall...

Page 10: ...10 5 15 5V DC Low Battery Alarm 10 7V 11 3V DC Output Voltage 110V 125V AC Low Battery Shutdown 10 2V 10 8V DC High Battery Shutdown 15 0V 16 0V DC Optimum Efficiency 85 Dimensions 8 5 L x 4 W x 2 2...

Page 11: ...s well as proof of purchase to the factory or a designated agent Schumacher Electric Corporation Warranty Service Department 1025 E Thompson P O Box 280 Hoopeston IL 60942 0280 Phone 800 621 5485 Hour...

Page 12: ...12 notes...

Reviews: