background image

2

IMPORTANT SAfETy INSTRUCTIONS

SAvE THESE INSTRUCTIONS

Before  using  your  PID-760,  read  and  understand  this 

Owner’s Manual.
•  Keep the inverter well ventilated in order to properly dis-

perse heat generated while it is in use. Make sure there 

are several inches of clearance around the top and sides 

and do not block the slots of the inverter.

•  Make sure the inverter is not close to any potential source 

of flammable fumes, gases or clothing. 

•  Keep the inverter dry.
•  DO NOT allow the inverter to come into contact with rain or 

moisture.

•  DO NOT operate the inverter if you, the inverter, the device 

being operated or any other surfaces that may come in 

contact with any power source are wet. Water and many 

other liquids can conduct electricity, which may lead to 

serious injury.

•  Do not place the inverter on or near heating vents, radia-

tors or other sources of heat.

•  Do not place the inverter in direct sunlight. The ideal air 

temperature for operation is between 50° and 80°F.

•  Do not use the inverter near an open engine compartment.
•  Only connect the power inverter to a 12-volt battery ac-

cessory outlet or 12-volt battery. Make sure the AC plug 

connection is tight.

Summary of Contents for PID-760

Page 1: ...668 0806 CAUTION Read all Safety Rules and Operating Instructions and follow them with each use of this product Schumacher Electric Corporation Mount Prospect IL 60056 U S A Send Warranty Product Repa...

Page 2: ...the inverter to come into contact with rain or moisture DONOToperatetheinverterifyou theinverter thedevice being operated or any other surfaces that may come in contact with any power source are wet W...

Page 3: ...PID 760 Power Inverter It is important to know the continuous wattage of the device you plan to use with the inverter The PID 760 must be used with devices drawing 760 watts or less If the wattage is...

Page 4: ...ghten so the wire is firmly attached Repeat the same process for the black wire 3 Connect the red positive battery cable to the positive battery terminal taking care to shield eyes clothing and hands...

Page 5: ...power than the inverter is capable of providing POWER SOURCE Your average automobile or marine battery at full charge will provide an ample power supply to the inverter for ap proximately 3 hours whe...

Page 6: ...ts LED DISPLAY The LED readouts identify the current status of the PID 760 VOLTAGE IN Voltage of vehicle s battery or Portable Power jump starter DC power source VOLTAGE OUT Voltage supplied to device...

Page 7: ...tart after the voltage drops below 15 5 volts hip The continuous load demand from the device exceeds 760 watts HoT Inverter is overheated and automatically turns off for a period of 1 3 minutes to coo...

Page 8: ...p m CST 2 Display shows Lob 12 Volt battery too low Recharge replace low battery 3 Display shows Voltage In between 10 5 and 11 0 Volts 12 Volt battery is low Recharge replace low battery Inverter wi...

Page 9: ...device Inverter will automatically reset after cooling PROBLEM Inverter Does Not Turn On Reason Solution 1 Poor contact at terminals Unplug and reinsert PID 760 2 Fuse is blown A blown fuse is usuall...

Page 10: ...10 5 15 5V DC Low Battery Alarm 10 7V 11 3V DC Output Voltage 110V 125V AC Low Battery Shutdown 10 2V 10 8V DC High Battery Shutdown 15 0V 16 0V DC Optimum Efficiency 85 Dimensions 8 5 L x 4 W x 2 2...

Page 11: ...s well as proof of purchase to the factory or a designated agent Schumacher Electric Corporation Warranty Service Department 1025 E Thompson P O Box 280 Hoopeston IL 60942 0280 Phone 800 621 5485 Hour...

Page 12: ...12 notes...