EN
39
Mains cable
The appliance will be delivered with a
4-wire mains cable (length: 150 cm)
for connection to 2-phase alternating
current with neutral conductor.
Fuses and switches are not included in
the scope of supply.
Warning
Risk of electric shock and risk of fire!
No extension cables, no multi-coupling
and no plug-in, mobile time switches
may be used.
Do not use plug-in, mobile timer
switches. The machine may not be
connected via an external switching
mechanism, which regularly switches
the machine on and off (e.g. timer
switch).
L1
brown
N
blue
L2
black
PE
yellow-green
400 V 2 N ~
PE
180
0
W
L2 L1 N
70
0
W
L1
L3 L2 L1 N
PE
PE
Heating
2,5 kW
Motor
0,3 kW
Fuse
10 AT
230 V 1 N ~
Reduced mains power
PE
180
0
W
L1 N
70
0
W
L1
L3 L2 L1 N
PE
PE
couper L2
cut off L2
Heating
1,8 kW
Motor
0,3 kW
Fuse
10 AT
Summary of Contents for WT14 EFH K