background image

EasyLED - Operating Instructions 

 

                                                                                                                              6/13 

 

To avoid unnecessary strain on the object by illuminating with visible light, reduce the 
brightness and duration of illumination to the absolute minimum level required! 
 
 
The instruments may be operated only with the power supply unit specified by SCHOTT and 
only within the designated mains voltage range. Otherwise, trouble-free operation and 
conformity with applicable standards cannot be guaranteed! 
 
The illumination units have been designed for operation in dry and dust-free interior rooms 
only! 
 
The system must not be used in explosive areas! 
 
Safe disconnection from the power supply is only guaranteed by pulling out the mains plug! 
 
When setting up, dismantling and converting the system, always switch off the instruments 
and pull the power plug! 
 
Never open or dismantle power supply units or illumination units. Refrain from performing 
any technical modifications. Repairs may only be carried out by the manufacturer or by its 
authorised customer service agencies. 
 
Please ensure that every user of the system has quick access to these operating 
instructions! 
 
The manufacturer is not liable for damage caused by failure to obey these instructions. 

 
 

Notes on operating the Transmitted Light Stage: 

 

The transmitted light stage has been developed for operation in a microscope stand or in 
another metallic heat sink. 
 
If the transmitted light stage is operated without the heat sink, the metal housing can heat up 
to approx. 50°C. However, the diffuser disc and the specimen field do not heat up to the 
same level. 
 
While causing an unpleasant sensation, the housing temperature mentioned above does not 
impair technical safety. The operation of the illumination is not affected in any way. 

 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for EasyLED Series

Page 1: ...nual Distribution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts AL5 5BZ United Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764334 F 4...

Page 2: ...EasyLED Operating Instructions 1 13 Operating instructions EasyLED Series Status March 2016...

Page 3: ...erating Instructions 2 13 Contents 1 System description 3 2 System overview 4 3 Important information 5 4 Start up procedure and operation 7 5 Maintenance 13 6 Technical data 13 7 Spare parts and acce...

Page 4: ...ine is distinguished by its particularly easy and ergonomic operation Running on direct current the EasyLED system is ideally suited for use with digital cameras It supports continuous dimming and com...

Page 5: ...syLED Operating Instructions 4 13 2 System overview A Transmitted Light Stage B Ringlight Ringlight Plus C Spot Illumination F 12 V DC power supply unit for Ringlight and Transmitted Light Stage A B C...

Page 6: ...mic injury ructions ormatio danger cauti m is intende s of stereom 2471 2008 t ass 0 Tran m is in comp ective c requireme cumentation n exception so with opti n on the o mination to ese instruc obser...

Page 7: ...nts and pull the power plug Never open or dismantle power supply units or illumination units Refrain from performing any technical modifications Repairs may only be carried out by the manufacturer or...

Page 8: ...y 100 240 V AC 50 60 Hz Attach the ringlight A to the microscope objective by tightening both thumb screws 2 so that the green control light 4 is facing the user The inner diameter of the ringlight A...

Page 9: ...le quarter circle and two quarter circle illumination as well as rotations in both directions Setting up segment mode With each press of the jog dial switch 6 the illumination switches from full circl...

Page 10: ...switch 6 is pressed and held for more than 2 seconds to the right the illuminated LED circle segment begins to automatically rotate in 1 8 circle steps to the right When the jog dial switch 6 is press...

Page 11: ...d Light Stage B in the notch provided on the microscope stand so that the green control light 9 is facing the user The basic version of the Transmitted Light Stage B has a diameter of 84 mm To connect...

Page 12: ...m 114 x 29 66 Type description EasyLED Transmitted Light Stage Dimensions OD x H mm 84 x 16 Relative humidity up to 31 C ambient temperature 85 31 C to 40 C ambient temperature linearly decreasing to...

Page 13: ...ng technical development 7 Spare parts and accessories Transmitted Light Stage 84 mm incl controller and power supply 600400 Filters Polarisation filter for spot system rotatable 600600 Polarisation f...

Page 14: ...This symbol means that electrical and electronic equipment must be disposed of separately from your household waste after they have reached their End of Life SCHOTT AG Lighting and Imaging have arran...

Page 15: ...ibution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts AL5 5BZ United Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764334 F 44 0 1582 7...

Reviews: