![SCHNIER 810489 Operating Manual Download Page 31](http://html1.mh-extra.com/html/schnier/810489/810489_operating-manual_1213809031.webp)
31
13. Malfunctions and their correction
In the event of a malfunction, first carry out a check of the AIR Flocker PRO using the points
listed below. If you are unable to rectify the fault, contact SCHNIER Elektrostatik GmbH. The
possibilities of contacting are listed on page 5 of these operating instructions.
malfunction
possible cause
remedial measures
The AIR Flocker Pro
cannot be switched on
No power supply
Check whether the power
plug of the AFP is plugged
in. Check the power cable
for mechanical damage.
Check whether the power
plug is correctly mounted
on the power cable.
Check whether fuses are
defective at the AFP
workstation.
Ground cable of the mains
cable is not connected or
interrupted
Check whether the ground
cable in the mains plug is
correctly connected. Check
the power cable for
mechanical damage.
No function
Damage to the high-voltage
cable due to leakage currents
Check the high-voltage
cable and replace it with a
new one if necessary
The knurled union nut has
loosened. As a result, the
contact between the high-
voltage plug-in unit and the
electrostatic manual spraying
device is interrupted.
Tighten the nut by hand.
Summary of Contents for 810489
Page 1: ...1 Art Nr 810489 80 kV 300 A...
Page 37: ...37...