II/6
SLM
GB
2. Press the quick-action coupling of the air
hose onto the plug nipple (item 01)
(Figure 1a).
Operation:
1. Attach the tool to the object being pro-
cessed.
2. Actuate the safety lever (item 08), if
available (Fig. 6a) and press the trigger
lever (item 02).
3. If there is no trigger lever (item 02):
Turn the rotary valve / air regulation
(item 03) accordingly (Fig. 7a).
4. If air regulation available:
adjust the torque at the air
regulation point (item 03) (Fig. 8a).
After use:
1. Disconnect the quick-action coupling
from the plug nipple (item 01)
(Figure 1b).
2. Remove the abrasive / tool.
2.5 Maintenance
L
Regular lubrication is required!
X
Oil using a maintenance unit
with filter pressure reducer and mist oiler.
X
Without mist oiler: oil daily by hand via the
plug nipple (item 01).
X
In the event of longer interruptions in op-
eration, also lubricate via the plug
nipple (item 01).
2.6 Decommissioning
Storage: Clean, dry, dust-free, not below
5° C.
Disposal: Dispose of the packaging / device
/ materials used according to applicable legal
regulations.
2.7 Warranty
Basic principle: complete unit in original
condition / proof of purchase.
Material and production defects are covered
by statutory provisions.
Excluded warranty claims: Wear or ex-
pendable parts, improper use, overloading /
incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.
2.8 Troubleshooting
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
Problem
Cause
Remedy
A Minimum or no
operating capacity
Air regulation (item 03) set-
ting incorrect
X
Adjust the air regulation setting
correctly
***
Abrasive / Tool worn
X
Replace abrasive / tool
*
Working pressure (flow pres-
sure) too low
X
Increase working pressure (flow
pressure) Observe maximum
working pressure
*
Compressor output too small
X
Use suitable output capacity
*
Hose diameter too small
X
Use correct hose diameter
*