The device was designed according to the state of the art and the approved safety stan-
dards. Nevertheless, its use may cause serious or fatal injury to the user or third persons,  
and/or an impairment of the device or of other material assets. 
The device may only be applied: 
- For its intended use in a faultless condition with regard to the safety requirements. 
- Malfunctions that could impair safety must be remedied immediately. 
- Personal protective equipment must be used according to the EC Directive 89/686/EEC.

The Operating Instructions must always be kept on hand where the device is operated. 
Apart from the Operating Instructions, the general and local valid regulations on accident 
prevention and environmental protection must be provided and complied with.

1.4  Informal Safety Measures

1.6  Intended Use

1.7  Dangers in Handling the Device

The device is intended exclusively to be used as a tension meter. Any other use or any 
use exceeding this intention will be regarded as misuse. Under no circumstances shall 
HANS SCHMIDT & Co GmbH be held liable for damage resulting from misuse. 
The intended use also includes: 
- Complying with all notices included in the Operating Instructions and observing all  
  inspection and maintenance works.

1.8  Copyright

1.9  Declaration of Conformity

The copyright on these Operating Instructions remains with the company 
HANS SCHMIDT & Co GmbH. 
These Operating Instructions are intended for the operating company and its personnel 
only. They contain instructions and notices that may only be reproduced on the prior writ-
ten permission of 
HANS SCHMIDT & Co GmbH 
and under indication of the complete reference data. 
Violations will be prosecuted.

Our mechanical tension meters do not belong to the EC machinery directive 2006/42/EG 
and do not have a CE mark.

1.5  Training of the Personnel

Only trained and instructed personnel is permitted to work with the device. The responsi-
bilities of the personnel must be clearly defined for mounting, commissioning, operation, 
setup, maintenance, and repair. Trainees may only work with the device under the super-
vision of experienced personnel.

The device must not be operated in potential explosive areas  
and must not come into contact with aggressive substances.

Summary of Contents for Q- 20

Page 1: ...Tension Meter Q Series Model Q Edition Q 04 2 E Operating Instructions Valid as of 01 02 2007 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...e 4 1 8 Copyright 4 1 9 Declaration of Conformity 4 2 Available Models 5 2 1 Specifications 5 2 2 Delivery Includes 6 2 3 Unpacking 6 3 Operation 6 3 1 Notes Before Starting Measurement 6 3 2 Fastening the Q Tensionmeter 7 3 3 Inserting the Material to be Measured 7 3 4 Verification of the Q calibration 8 4 Service and Maintenance 9 4 1 Rollers 9 5 Cleaning 9 6 Verification Intervals 9 6 1 Verific...

Page 3: ...the device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instru...

Page 4: ...shall HANS SCHMIDT Co GmbH be held liable for damage resulting from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright 1 9 Declaration of Conformity The copyright on these Operating Instructions remains with the company HANS SCHMIDT Co GmbH These Operating Instructions are intended...

Page 5: ...20 300 PA 0 20 mm Ø Q 500 50 500 PA 0 20 mm Ø Q 1000 50 1000 PA 0 30 mm Ø The standard instruments can have the following modifications or changes Deviating measuring ranges Material of the rollers Adjustment to other materials The Operating Instructions can also be used for these instruments as their handling is the same 2 1 Specifications Calibration According to SCHMIDT factory procedure Accura...

Page 6: ...articular Chapter 1 Basic Safety Notices You must not operate the device before Before working with the device you must put on your personal protective equipment if necessary For example eye protectors gloves etc To avoid damage do not move the center roller by hand Tensions that exceed the measuring range of the device by more than 100 may cause a permanent deformation of the measuring spring and...

Page 7: ...the Material to be Measured Thread the material to be measured carefully through the MEASURING ROLLER and ROLLER GUIDES as shown in fig 3 3 To avoid damage do not move the center roller by hand using force It is important to ensure that the MEASURED MATERIAL runs smoothly through the ROLLER GUIDES and the MEASURING ROLLER You can now read the measured tension on the SCALE MEASURING ROLLER ROLLER G...

Page 8: ...ed the instrument has to be recalibrated or repaired For recalibration return the tension meter to the factory All tension meters are calibrated with standard materials such as polyamide monofilament PA according the SCHMIDT factory procedure The filament sizes are noted in Chapter 2 Any difference in PROCESS MATERIAL size and rigidity from the standard material may cause a deviation of the accura...

Page 9: ...r s Quality Assurance Department based on the user s experience Assuming normal operating time and load as well as careful handling of the tension meter we recommend a verification interval of 1 year 6 Verification Intervals 5 Cleaning You should regularly inspect the rollers to assure that they are running easily and smoothly You can replace the rollers yourself as necessary When ordering spare r...

Page 10: ...y customer No Yes No Yes No Yes Vertification of the calibration Visual inspection and functional test Values within specification Prepare certification for incoming calibration Determination of costs Make of cost estimate Repair and adjustment Verification of the calibration Calibration label on the instrument No Invoice scrapping and disposal Invoice repair and calibration services and dispatch ...

Page 11: ... to our service department Please indicate in your order whether you require an Inspection Certificate 3 1 according to DIN EN 10204 8 Repairs HANS SCHMIDT Co GmbH Schichtstr 16 D 84478 Waldkraiburg Germany Service address Shipping instructions We kindly ask for return free of charge for us if possible by airmail parcel All occurring charges if any such as freight customs clearance duty etc will b...

Page 12: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 60 years Worldwide e mail info hans schmidt com Internet http www ...

Reviews: