background image

TESK

Operating instructions
Hinge safety switch

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version 
in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be 
found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is provi-
ded without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

 Safety classiication

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2  Adjustment and inspection of the switching angle . . . . . . . . . . . . . . 4
3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 5
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.3  Switch travel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Appendix

7.1 

Wiring coniguration and connector accessories

. . . . . . . . . . . . . . . 6

7.2  Door gap calculation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7.3 

Load speciications

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.4  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

 x.000 / November 2013 / v

.A. - 103005958-EN / 

A

 / 2013-1

1-18 / 

AE-Nr

.

EN

Operating instructions. . . . . . . . . . . .pages 1 to 10

Translation of the original operating instructions

Summary of Contents for TESK- 02 Series

Page 1: ...nce with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulation...

Page 2: ...n which the hazardous condition is terminated without delay e g run on movements when the safety guard is opened The user must evaluate and design the safety chain in accordance with the relevant standards and on the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC...

Page 3: ...r assembly and adjustment Fig 3 A A Fig 3 Legend A Drill and pin in this area The hinge safety switch must not be used as an end stop Any mounting position The mounting position however is chosen so that the components are preferably fitted in the upper part of the safety guard to avoid the ingress of dirt and soiling as well as damage to the components In case of painting activities the component...

Page 4: ...nce of the switch with the safety technical requirements of the application must be checked See Section 7 2 Door gap calculation 4 After the switching angle has been set and checked the blanking plug for the adjustment opening located at the rear of the adjustment tool must be inserted in the adjustment opening 1 and torn down by making lateral movements 2 with the tool Fig 7 1 2 Fig 6 Fig 7 After...

Page 5: ...losed TESK 22L TESK 13L WH 11 VT 23 12 BK 24 RD BN 31 32 BU GY 43 44 PK PE GN YE WH 11 VT 23 12 BK 24 RD BN 31 32 BU GY 41 42 PK PE GN YE TESK 12L TESK 02L WH 11 VT 23 12 BK 24 RD BN 31 32 BU PE GN YE BN 21 22 BU 12 BK WH 11 PE GN YE TESK 11L WH 11 BN 23 12 BK 24 BU PE GN YE TESK 22ST TESK 13ST 11 23 12 24 31 32 1 2 3 4 5 6 7 8 43 44 5 8 4 3 2 1 7 6 11 23 12 24 31 32 41 42 1 2 3 4 5 6 7 8 5 8 4 3 ...

Page 6: ...or IP67 M12 5 pole 5 x 0 25 mm 1 BN 1 BN WH 2 WH 2 WH BN Cable length Part number 3 BU 3 BU GN 5 0 m 15 0 m 101209949 101209948 4 BK 4 BK YE 5 GY 5 GY GY Connector plug ST2 M12 8 pole 5 8 4 3 2 1 7 6 Pin configuration of the connector Colour code or conductor numbering of the below mentioned Schmersal connectors possible colour code of other commercially available connectors to EN 60947 5 2 2007 D...

Page 7: ...4 146 2 166 9 187 6 208 3 1 250 65 4 87 2 108 9 130 6 152 3 173 9 195 4 217 0 1 300 68 0 90 6 113 2 135 8 158 4 180 8 203 3 225 6 1 350 70 6 94 1 117 6 141 0 164 4 187 8 211 1 234 3 1 400 73 2 97 6 122 0 146 3 170 5 194 7 218 9 243 0 1 450 75 8 101 1 126 3 151 5 176 6 201 7 226 7 251 7 1 500 78 5 104 6 130 7 156 7 182 7 208 7 234 5 260 3 β Door opening angle C Door width in mm D is the door gap in...

Page 8: ... 750 750 700 600 550 550 500 500 450 400 350 300 up to 2600 750 700 600 500 450 450 400 400 400 400 350 300 B D C F 0 5 5 x H H 8 H 5 H 8 H 5 H 5 0 6 x H H C Use of one hinge switch and an additional hinge D Use of one hinge switch and two additional hinges With larger doors the have three hinges make sure the two of the hinges are located in the upper third We recommend that the hinge switch is p...

Page 9: ...e Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal November 27 2013 Authorised signature Philip Schmersal Managing Director EC Declaration of conformity Translation of the original Declaration of Conformity K A Schmersal GmbH Co KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 42279 Wuppertal ...

Page 10: ...o KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...