schmersal SLG 420 series Operating Instructions Manual Download Page 3

3

SLG 420

Operating instructions

Safety light grid

EN

2.5  Technical data

Standards:

 

EN 61496--1, CLC/TS 61496-2, 

EN ISO 13849, EN 62061

Material of the enclosure:

 

Aluminium

Number of beams:

 

2, 3, 4 beams

Protection field heights:

 

500 mm, 800 mm, 900 mm

Detection ability for test bodies:

 

2 beams  with resolution 500 mm *1  

3 beams with resolution 400 mm *1  

4 beams with resolution 300 mm *1

Range of the protection field:

 

0,3 … 18,0 m 

8,0 … 40,0 m

Response time:

 

2 - 4 beams:10 ms (Standard) 2 - 4 beams: 15 

ms(beam coding A)

Rated operating voltage:

 

24 VDC ±10% (PELV) supply unit to 

EN 60204 (power drop > 20 ms)

Operating current:

 

400 mA max. + 0.5 A (OSSD load + output signal 

quality load)

 

Wave length of the sensor:

 

860 nm

Safety outputs (OSSD1, OSSD2):

 

2 x PNP-type semi-conductor, 

short-circuit proof

Switching voltage HIGH¹:

 

15 V … 28,8 V

Switching voltage LOW¹:

 

0 V … 2 V

Switching current:

 

0 mA … 500 mA

Leakage current²:

 

1 mA

Load capacity:

 

2 µF

Load inductance:

 

2 H

Admissible conduction resistance

 

between OSSD and load:

 

2,5 Ω

Supply cable:

 

1 Ω

Contactor control (EDM)

 

Input voltage HIGH:

 

17 V … 29 V

Input voltage LOW:

 

0 V … 2,5 V

Input current HIGH:

 

3 mA … 10 mA

Input current LOW:

 

0 mA … 2 mA

Input restart interlock (manual reset) 

Input voltage HIGH:

 

17 V … 29 V

Input voltage LOW:

 

0 V … 2,5 V

Input current HIGH:

 

3 mA … 10 mA

Input current LOW:

 

0 mA … 3 mA

Function:

 

Protective mode, start and restart interlock 

(manual reset), contactor control, beam blanking

Signal times

 

Contactor control:

 

50 ms … 500 ms, adjustable

Restart interlock (manual reset):

 

50 ms … 1,0 s, signal trans-

mission in case of trailing edge

Start interlock:

 

250 ms … 1500 ms, adjustable

LED indications transmitter:

 

Transmitting, status

LED indications receiver:

 

OSSD ON, OSSD OFF, restart, signal 

reception, blanking, multifunction

Connection:

 

M12 connector plug with metal thread, receiver 

8-pole, transmitter 4-pole

Ambient temperature:

 

−10° C … +50° C

Storage temperature:

 

−25° C … +70° C

Interface:

 

Diagnostics and function setting

Protection class:

 

IP67 (IEC 60529)

Resistance to vibrations:

 

10 - 55 Hz to IEC 60068-2-6

Resistance to shock:

 

10 g; 16 ms; to IEC 60068-2-29

Year of construction:

 

as of 2010 version 1.0

*1 resolution = beam di beam diameter 10 mm

²)  In case of failure, the leakage current at the most flows to the OSSD 

cable.  The downstream control element must recognise this state as 

LOW. A safety PLC must detect this state.

2.6  Response time (reaction time)

Standard version

The response time of the SLG 420 safety light grid depends on the 

number of light beams and the beam coding A.

Resolution 14

Beams  

[Number]

Beam 

distance 

[mm]

Respon-

se time  

[ms]

Response time with 

beam coding A  

[ms]

Weight  

 

[kg]

2

500

10

15

2.5

3

400

10

15

3.5

4

300

10

15

3.6

2.7  Safety classification

Standards:

 

EN ISO 13849-1, EN 62061

PL:

 

up to e

Control category:

 

up to 4

PFH value:

 

7.42 x 10

-9 /

 h

SIL:

 

up to 3

Service life:

 

20 years

2.8  Functions

The system consists of a receiver and a transmitter. For the described 

functions, no further switching elements are required. For the diag-

nostics and function selection, a user-friendly PC-software is offered as 

accessory.

For the connection to a PC, the NSR-0801 BUS converter is required 

(not included in delivery).

The system for the version SLC 420 has the following features:

•  Protective mode (automatic start after release of the protected field)

•  Start interlock

•  Restart interlock (manual reset)

•  Contactor control EDM

•  Beam coding

•  Blanking of one beam (only for 3- and 4-beam light grids)

Factory setting

The SLG 420 system features many functions without additional de-

vices. The following table includes an overview of the possible functions 

and the configuration of the condition on delivery.

Function

Factory setting  Configuration

Protective mode

not active

External wiring

Restart interlock  
(manual reset)

not active

External wiring

Fixed blanking

not active

With BUS converter 
NSR-0801 and PC-software

Contactor control

not active

With BUS converter 
NSR-0801 and PC-software

Start interlock

not active

With BUS converter 
NSR-0801 and PC-software

Beam coding

not active

With BUS converter 
NSR-0801 and PC-software

2.8.1 Protective mode

The protective mode switches the OSSD outputs to ON state (protec-

tion field not interrupted), without external release of a switching device.

This type of protection generates an automatic restart of the machine if 

the protection field is not interrupted.

This operating mode may only be chosen in conjunction with 

the restart interlock (manual reset) of the machine.

This operating mode must not be chosen, when persons can 

step behind the protection field.

Summary of Contents for SLG 420 series

Page 1: ...r malfunctions Warning Failure to comply with this warning notice could lead to physical injury and or damage to the machine 1 4 Appropriate use The products described in these operating instructions...

Page 2: ...modifications to the device 2 Product description 2 1 Ordering code This operating instructions manual applies to the following types SLG 420 E R RF No Option Description Distance between outermost be...

Page 3: ...ure the leakage current at the most flows to the OSSD cable The downstream control element must recognise this state as LOW A safety PLC must detect this state 2 6 Response time reaction time Standard...

Page 4: ...ated The standard IEC TS 62046 includes information which describes possibly required additional measures to prevent a person from reaching a hazard through the blanking areas of a protection field Af...

Page 5: ...ired to 24VDC they are in ON state as a result of which they are unable to stop a hazardous situation occuring on the application machine The safety inspections must be conducted regularly The SLG 420...

Page 6: ...safety distance between the safety light grid and the hazardous point must always be respected and observed If a person reaches the hazardous point before the hazar dous movement has come to standstil...

Page 7: ...t end cap L2 Mounting distance mm between floor and slotted hole centre diagnostic window SLG 420 3 beam version SLG 420 E R0800 03 RF 48 7 49 6 L2 80 42 L1 51 B C 31 5 6 A A 97 86 A B C L1 L2 400 948...

Page 8: ...A B C L1 L2 300 1088 1124 209 203 L1 Mounting distance mm between floor and slotted hole centre short end cap L2 Mounting distance mm between floor and slotted hole centre diagnostic window Centre fi...

Page 9: ...activated Protective mode bridge 2 By bridging DIAG OUT pin 6 and authorised operation pin 1 the protective mode is activated K1 K2 Relay for processing the switching outputs OSSD 1 OSSD 2 Kn1 Kn2 Au...

Page 10: ...Description 5 8 4 3 2 1 7 6 1 WH Restart Input 2 BN 24 V DC Power supply 3 GN OSSD 1 Safety output 1 4 YE OSSD 2 Safety output 2 5 GY Diagnostic IN Input diagnostic data 6 PK Diagnostic OUTOutput diag...

Page 11: ...luding the following steps is recommended 1 The safety light grid does not have any visible damages 2 The optics cover is not scratched or soiled 3 Hazardous machinery parts can only be accessed by pa...

Page 12: ...configuration settings by means of the NSR 0801 BUS converter repeat the teach process with blanking 6 3 Extended diagnostic By means of the optional configuration software SLG 420 and the NSR 0801 BU...

Page 13: ...orized for the compilation of the technical documentation Ulrich Loss M ddinghofe 30 42279 Wuppertal Notified body for the prototype test T V Nord Cert GmbH Langemarckstr 0 45141 Essen ID n 0044 EC pr...

Page 14: ...Safety Control GmbH Am Industriepark 33 D 84453 M hldorf Inn Telefon 49 0 86 31 187 9 60 Telefax 49 0 86 31 187 9 61 E Mail info safetycontrol com...

Reviews: