background image

SLC 220

SLG 220

Operating instructions

Safety light curtain / safety light grid

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure  the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete ver-

sion in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operat-

ing instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards to 

be complied with as well as other technical specifications for the selec-

tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional informa-

tion.

Caution: 

Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning: 

Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 

versions listed below or for the applications authorised by the manufac-

turer. Detailed information regarding the range of applications can be 

found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-

tions manual, the country-specific installation standards as well as all 

prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet: www.

schmersal.net.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Scope of delivery and accessories  . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.6  Response time (reaction time). . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.7  Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.8  Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.9  Cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3  Mounting

3.1  General conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.2  Protection ield and approach  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.3  Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.4  Safety distance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.5  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4  Electrical connection

4.1  Wiring example default  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

5  Set-up and maintenance

5.1  Check before start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5.3  Regular check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5.4  Half-yearly inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5.5  Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

6  Diagnostic

6.1  LED status information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

6.2  Fault diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

6.3  Extended diagnostic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

8  Appendix

8.1  Contact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

9  Declaration of conformity

9.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

x.000 / v

.A. / 04.201

1 / BZ-Nr

. 53501-7V900 / 

Teile-Nr

. 1214170-EN / 

Ausgabe C

FR

Vous trouverez la version  

actuelle du mode d’emploi dans 

votre langue nationale officielle 

sur l’Internet,  

www.schmersal.net.

ES

Encontrará el manual de  

instrucciones actual en su  

idioma oficial de la UE en 

nuestra página de Internet  

www.schmersal.net.

NL

U vindt de huidige versie van de 

gebruikshandleiding in uw  

officiële landstaal op het Inter-

net, www.schmersal.net.

IT

Il manuale d‘istruzioni aggior-

nato nella vostra lingua (lingua 

ufficiale UE) è scaricabile in 

Internet all‘indirizzo  

www.schmersal.net.

JP

EU公用語で書かれた最新の取扱

説明書は,インターネッ 

(www.schmersal.net) からダウ

ンロードできます。

EN

Operating instructions. . . . . . . . . . . .pages 1 to 14

Translation of the original operating instructions

Summary of Contents for SLC 220

Page 1: ...ct description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailin...

Page 2: ...nge 0 3 m 6 m H Range 5 m 30 m high range M Master function S Slave function Only if the information described in this operating instruc tions manual are realised correctly the safety function and the...

Page 3: ...l reset 20 ms 1 0 s signal trans mission in case of trailing edge Start interlock 250 ms 1500 ms adjustable LED indications transmitter Transmitting status restart LED indications receiver OSSD ON OSS...

Page 4: ...ton 2 8 3 Fixed blanking The SLC 220 can blank stationary parts in the protection field Multiple protection field areas can be blanked Fixed blanking area E1 R1 The range of the fixed blanking can be...

Page 5: ...nsion is possible up to max 96 lines and a pro tection field height of 2 45 m with the same resolution The connection of the systems master and slave is realised with the pre wired connector KA 0907 3...

Page 6: ...the following elements Stopping time of the machine calculation by run on time measure ment Response time of the machine and the safety light curtain and the downstream relay entire safety guard Appr...

Page 7: ...41 mm The following mounting heights to EN 999 must be observed Number of beams Mounting height above reference floor Floor in mm 2 400 900 3 300 700 1100 4 300 600 900 1200 The successor standards of...

Page 8: ...2 1289 1 8 SLC 220 E R1375 30 RFB 1375 0 8 1422 1 5 1439 2 0 SLC 220 E R1525 30 RFB 1525 0 8 1572 1 5 1589 2 0 SLC 220 E R1675 30 RFB 1675 0 8 1722 1 5 1739 2 0 All versions with resolution 30 and 80...

Page 9: ...fety light curtain safety light grid EN Accessories Mounting kit MS 1000 5 5 5 14 25 39 27 46 5 5 8 35 20 Centre support MS 1010 3 8 19 1 42 4 38 1 38 1 43 2 46 5 27 20 30 43 12 8 19 2 5 5 3 5 R 2 5 C...

Page 10: ...RS485 B grey 24V brown 0V blue RS485 A pink RS485 B grey Signal quality white 24V brown 0V blue OSSD2 yellow OSSD1 green Earth connection Restart interlock active this connection is omitted connect S2...

Page 11: ...ies Conditions For safety reasons all inspection results must be archived The operat ing principle of the SLC SLG and the machine must be known in order to be able conducting an inspection If the fitt...

Page 12: ...D OFF contactor control input must show 24V Switch on only after POWER OFF ON 1 flashes Receiver configuration error or communication error Check transmitter and receiver configuration reparameterize...

Page 13: ...manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal...

Page 14: ...h Loss M ddinghofe 30 42279 Wuppertal Notiied body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n 0044 EC prototype test certiicate n 44 205 10 555867 004 Safety Control G...

Reviews: