background image

3

SLC 220

SLG 220

Operating instructions

Safety light curtain / safety light grid

EN

2.5  Technical data

Standards:

 

EN 61496-1; CLC/TS 61496-2; 

EN ISO 13849; EN 62061

Material of the enclosure: 

Aluminium

Number of beams: 

SLC 220: 6 - 66 (default) – max. 96 (cascaded) 

SLG 220: 2, 3, 4 beams

Protection field heights: 

SLC 220: 175 mm -1675 mm default 

325 mm - 2450 mm cascaded system  

SLG 220: 500 mm, 800 mm, 900 mm

Beam distance: 

SLG 220: 300 mm, 400 mm, 500 mm

Response time: 

SLC 220: 9 ms - 65 ms 

SLG 220: 12 ms - 19 ms

Detection sensitivity for test bodies: 

30 mm, 80 mm

Range of the protection field: 

SLC 220: 0,3 m - 6 m

4 m - 14 m (high range) 

SLG 220: 0,3 m - 6 m 

5 m - 30 m (high range)

Rated operating voltage: 

24 VDC ±10% (PELV) 

supply unit to EN 60204  

(power drop > 20 ms)

Operating current:

 

400 mA max. + 0.5 A 

(OSSD load + output signal quality load)

Wave length of the sensor: 

880 nm

"Safety outputs (OSSD1, OSSD2)": 

2 x PNP-type semi-conductor, 

short-circuit proof

Switching voltage HIGH¹: 

15 V - 28.8 V

Switching voltage LOW¹: 

0 V - 2 V

Switching current: 

0 mA - 200 mA

Leakage current²: 

1 mA

Load capacity: 

2 µF

Load inductance: 

2 H

Admissible conduction resistance between OSSD and load: 

2.5 Ω

Supply cable: 

1 Ω

Contactor control (EDM):

Input voltage HIGH (inactive): 

17 V - 29 V

Input voltage LOW (active): 

0 V - 2.5 V

Input current HIGH: 

3 mA - 10 mA

Input current LOW: 

0 mA - 2 mA

Input restart interlock

Input voltage HIGH (active): 

17 V - 29 V

Input voltage LOW (inactive): 

0 V - 2.5 V

Input current HIGH: 

11 mA - 120 mA

Input current LOW: 

0 mA - 2 mA

Function: 

SLC 220: Protective mode, start and restart interlock, contac-

tor control Cascading: beam blanking fixed SLG 220: Start and restart 

interlock, contactor control

Signal times: 

Contactor control: 

20 ms - 300 ms

Restart interlock (manual reset):

 

20 ms … 1,0 s, signal trans-

mission in case of trailing edge

Start interlock: 

250 ms - 1500 ms, adjustable

LED indications transmitter: 

Transmitting, status, restart

LED indications receiver: 

OSSD ON, OSSD OFF, signal recep-

tion, blanking

Connection: 

M12 connector plug, 8-pole with metal thread

Cascading: 

  M12 connector plug with metal thread, id. to stand-alone

Ambient temperature:

 

−10° C … +50° C

Storage temperature:

 

−25° C … +70° C

Interface: 

Diagnostics and function setting

Protection class:

 

IP65 (IEC 60529)

Resistance to vibrations: 

10 - 55 Hz to IEC 60068-2-6

Resistance to shock: 

10 g; 16 ms; to IEC 60068-2-29

Year of construction: 

as of 2010 version 1.0

¹) To IEC 61131-2 

²)  In case of failure, the leakage current at the most flows to the OSSD 

cable. The downstream control element must recognise this state as 

LOW. A safety PLC must detect this state.

2.6  Response time (reaction time)

The response time depends on the hight of the protected field, the 

resolution and the number of light beams.

Resolution 30 mm
Protection field 

height

[mm]

Beams

[Number]

Response time

[ms]

Weight

[kg]

175

6

12

0.7

250

9

12

0.9

325

12

12

1.0

475

18

16

1.3

625

24

19

1.8

775

30

23

1.9

925

36

27

2.2

1075

42

30

2.5

1225

48

34

2.8

1375

54

37

3.1

1525

60

41

3.4

1675

66

45

3.7

1850

72*

49

2000

78*

54

2150

84*

57

2300

90*

61

2450

96*

65

Resolution 80 mm
Protection field 

height

[mm]

Beams

[Number]

Response time

[ms]

Weight

[kg]

250

3

9

0.9

325

4

9

1.0

475

6

10

1.3

625

8

12

1.8

775

10

13

1.9

925

12

15

2.2

1075

14

16

2.5

1225

16

18

2.8

1375

18

19

3.1

1525

20

20

3.4

1675

22

21

3.7

1850

24*

23

2000

26*

24

2150

28*

25

2300

30*

26

2450

32*

27

* for systems with cascading

SLG 220 multi-beam version

Beam distance

[mm]

Beams

[Number]

Response time

[ms]

Weight

[kg]

500

2

12

1.4

400

3

16

2.0

300

4

19

2.1

2.7  Safety classification

Standards:

 

EN ISO 13849-1, EN 62061

PL: 

up to d

Control category: 

up to 2

PFH-value: 

3.59 x 10

-8

 / h

SIL: 

up to 2

Service life: 

20 years

Summary of Contents for SLC 220

Page 1: ...ct description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailin...

Page 2: ...nge 0 3 m 6 m H Range 5 m 30 m high range M Master function S Slave function Only if the information described in this operating instruc tions manual are realised correctly the safety function and the...

Page 3: ...l reset 20 ms 1 0 s signal trans mission in case of trailing edge Start interlock 250 ms 1500 ms adjustable LED indications transmitter Transmitting status restart LED indications receiver OSSD ON OSS...

Page 4: ...ton 2 8 3 Fixed blanking The SLC 220 can blank stationary parts in the protection field Multiple protection field areas can be blanked Fixed blanking area E1 R1 The range of the fixed blanking can be...

Page 5: ...nsion is possible up to max 96 lines and a pro tection field height of 2 45 m with the same resolution The connection of the systems master and slave is realised with the pre wired connector KA 0907 3...

Page 6: ...the following elements Stopping time of the machine calculation by run on time measure ment Response time of the machine and the safety light curtain and the downstream relay entire safety guard Appr...

Page 7: ...41 mm The following mounting heights to EN 999 must be observed Number of beams Mounting height above reference floor Floor in mm 2 400 900 3 300 700 1100 4 300 600 900 1200 The successor standards of...

Page 8: ...2 1289 1 8 SLC 220 E R1375 30 RFB 1375 0 8 1422 1 5 1439 2 0 SLC 220 E R1525 30 RFB 1525 0 8 1572 1 5 1589 2 0 SLC 220 E R1675 30 RFB 1675 0 8 1722 1 5 1739 2 0 All versions with resolution 30 and 80...

Page 9: ...fety light curtain safety light grid EN Accessories Mounting kit MS 1000 5 5 5 14 25 39 27 46 5 5 8 35 20 Centre support MS 1010 3 8 19 1 42 4 38 1 38 1 43 2 46 5 27 20 30 43 12 8 19 2 5 5 3 5 R 2 5 C...

Page 10: ...RS485 B grey 24V brown 0V blue RS485 A pink RS485 B grey Signal quality white 24V brown 0V blue OSSD2 yellow OSSD1 green Earth connection Restart interlock active this connection is omitted connect S2...

Page 11: ...ies Conditions For safety reasons all inspection results must be archived The operat ing principle of the SLC SLG and the machine must be known in order to be able conducting an inspection If the fitt...

Page 12: ...D OFF contactor control input must show 24V Switch on only after POWER OFF ON 1 flashes Receiver configuration error or communication error Check transmitter and receiver configuration reparameterize...

Page 13: ...manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal...

Page 14: ...h Loss M ddinghofe 30 42279 Wuppertal Notiied body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n 0044 EC prototype test certiicate n 44 205 10 555867 004 Safety Control G...

Reviews: