3
SLC 220
SLG 220
Operating instructions
Safety light curtain / safety light grid
EN
2.5 Technical data
Standards:
EN 61496-1; CLC/TS 61496-2;
EN ISO 13849; EN 62061
Material of the enclosure:
Aluminium
Number of beams:
SLC 220: 6 - 66 (default) – max. 96 (cascaded)
SLG 220: 2, 3, 4 beams
Protection field heights:
SLC 220: 175 mm -1675 mm default
325 mm - 2450 mm cascaded system
SLG 220: 500 mm, 800 mm, 900 mm
Beam distance:
SLG 220: 300 mm, 400 mm, 500 mm
Response time:
SLC 220: 9 ms - 65 ms
SLG 220: 12 ms - 19 ms
Detection sensitivity for test bodies:
30 mm, 80 mm
Range of the protection field:
SLC 220: 0,3 m - 6 m
4 m - 14 m (high range)
SLG 220: 0,3 m - 6 m
5 m - 30 m (high range)
Rated operating voltage:
24 VDC ±10% (PELV)
supply unit to EN 60204
(power drop > 20 ms)
Operating current:
400 mA max. + 0.5 A
(OSSD load + output signal quality load)
Wave length of the sensor:
880 nm
"Safety outputs (OSSD1, OSSD2)":
2 x PNP-type semi-conductor,
short-circuit proof
Switching voltage HIGH¹:
15 V - 28.8 V
Switching voltage LOW¹:
0 V - 2 V
Switching current:
0 mA - 200 mA
Leakage current²:
1 mA
Load capacity:
2 µF
Load inductance:
2 H
Admissible conduction resistance between OSSD and load:
2.5 Ω
Supply cable:
1 Ω
Contactor control (EDM):
Input voltage HIGH (inactive):
17 V - 29 V
Input voltage LOW (active):
0 V - 2.5 V
Input current HIGH:
3 mA - 10 mA
Input current LOW:
0 mA - 2 mA
Input restart interlock
Input voltage HIGH (active):
17 V - 29 V
Input voltage LOW (inactive):
0 V - 2.5 V
Input current HIGH:
11 mA - 120 mA
Input current LOW:
0 mA - 2 mA
Function:
SLC 220: Protective mode, start and restart interlock, contac-
tor control Cascading: beam blanking fixed SLG 220: Start and restart
interlock, contactor control
Signal times:
Contactor control:
20 ms - 300 ms
Restart interlock (manual reset):
20 ms … 1,0 s, signal trans-
mission in case of trailing edge
Start interlock:
250 ms - 1500 ms, adjustable
LED indications transmitter:
Transmitting, status, restart
LED indications receiver:
OSSD ON, OSSD OFF, signal recep-
tion, blanking
Connection:
M12 connector plug, 8-pole with metal thread
Cascading:
M12 connector plug with metal thread, id. to stand-alone
Ambient temperature:
−10° C … +50° C
Storage temperature:
−25° C … +70° C
Interface:
Diagnostics and function setting
Protection class:
IP65 (IEC 60529)
Resistance to vibrations:
10 - 55 Hz to IEC 60068-2-6
Resistance to shock:
10 g; 16 ms; to IEC 60068-2-29
Year of construction:
as of 2010 version 1.0
¹) To IEC 61131-2
²) In case of failure, the leakage current at the most flows to the OSSD
cable. The downstream control element must recognise this state as
LOW. A safety PLC must detect this state.
2.6 Response time (reaction time)
The response time depends on the hight of the protected field, the
resolution and the number of light beams.
Resolution 30 mm
Protection field
height
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
175
6
12
0.7
250
9
12
0.9
325
12
12
1.0
475
18
16
1.3
625
24
19
1.8
775
30
23
1.9
925
36
27
2.2
1075
42
30
2.5
1225
48
34
2.8
1375
54
37
3.1
1525
60
41
3.4
1675
66
45
3.7
1850
72*
49
2000
78*
54
2150
84*
57
2300
90*
61
2450
96*
65
Resolution 80 mm
Protection field
height
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
250
3
9
0.9
325
4
9
1.0
475
6
10
1.3
625
8
12
1.8
775
10
13
1.9
925
12
15
2.2
1075
14
16
2.5
1225
16
18
2.8
1375
18
19
3.1
1525
20
20
3.4
1675
22
21
3.7
1850
24*
23
2000
26*
24
2150
28*
25
2300
30*
26
2450
32*
27
* for systems with cascading
SLG 220 multi-beam version
Beam distance
[mm]
Beams
[Number]
Response time
[ms]
Weight
[kg]
500
2
12
1.4
400
3
16
2.0
300
4
19
2.1
2.7 Safety classification
Standards:
EN ISO 13849-1, EN 62061
PL:
up to d
Control category:
up to 2
PFH-value:
3.59 x 10
-8
/ h
SIL:
up to 2
Service life:
20 years