8
Operating instructions
Safety light curtain / safety light grid
SLC 220
SLG 220
EN
3.5 Dimensions
All measurements in mm.
SLC 220 default transmitter and receiver
>
60
7,5
20
40
27,5
A
B
C
19,5
Marking for protection field
and optical axis 1)
Dimensioning connector plug
Ø 40
+ -
0,1
7
14.5
M12
Type
A
Protection
field height
B
Mounting
dimension
C
Total
length
SLC 220-E/R0175-30-RFB 175 ± 0.5
234.5 ± 1.0 251.5 ± 1.5
SLC 220-E/R0250-30-RFB 250 ± 0.5
297 ± 1.0
314 ± 1.5
SLC 220-E/R0325-30-RFB 325 ± 0.5
372 ± 1.0
389 ± 1.5
SLC 220-E/R0475-30-RFB 475 ± 0.5
522 ± 1.0
539 ± 1.5
SLC 220-E/R0625-30-RFB 625 ± 0.6
672 ± 1.0
689 ± 1.5
SLC 220-E/R0775-30-RFB 775 ± 0.6
822 ± 1.0
839 ± 1.5
SLC 220-E/R0925-30-RFB 925 ± 0.6
972 ± 1.2
989 ± 1.8
SLC 220-E/R1075-30-RFB 1075 ± 0.7
1122 ± 1.2
1139 ± 1.8
SLC 220-E/R1225-30-RFB 1225 ± 0.7
1272 ± 1.2
1289 ± 1.8
SLC 220-E/R1375-30-RFB 1375 ± 0.8
1422 ± 1.5
1439 ± 2.0
SLC 220-E/R1525-30-RFB 1525 ± 0.8
1572 ± 1.5
1589 ± 2.0
SLC 220-E/R1675-30-RFB 1675 ± 0.8
1722 ± 1.5
1739 ± 2.0
All versions with resolution 30 and 80 mm as well as variant (-H) range
from 4.0 to 14.0 m and cascaded systems have identical dimensions
with the same protection field height.
1) For the SLC 220-E/R0175-30-RFB type, the dimension changes from
19.5 mm to 32 mm due to the extended profile length. The protection
field is marked with an individual marking
SLG 220 multi-beam transmitter and receiver
54,75
42,25
>
60
20
40
A
B
C
L2
L1
Indication of measurements
Type
A
Beam
distance
B
Fixing
± 1.0
C
Total
length
± 1.5
L1 L2
SLG 220-E/R0500-02-RF 500
597
614
358 345
SLG 220-E/R0800-03-RF 400
897
914
258 245
SLG 220-E/R0900-04-RF 300
997
1014
258 245
L1 = Mounting distance (mm) between fixing surface and centre slotted
hole (short end cap)
L2 = Mounting distance (mm) between fixing surface and centre slotted
hole (diagnostic window)