background image

10

Operating instructions

Safety light curtain / safety light grid

SLC 220

SLG 220

EN

4.  Electrical connection

4.1  Wiring example default

K1

K2

S2

Erdung

S1

kn1

kn2

E 1

2

7

2

3

4

7

1

1

6

5

6

5

3

4

Special cable for 

cascading

Extension by master 

and slave

Basic system:

Default

S1 only for external test

Optional function:

Use input only for contactor 

control - activation through 

NSR-0700

If the function is not activated, 

do not wire the input.

Cont

ac

tor contr

ol (gr

een)

Test input (y

ellow)

Rest

ar

t int

er

lock (whit

e)

RS485(A) (pink)

RS485(B) (gr

ey)

+24V (br

own)

0V (blue)

RS485(A) (pink)

RS485(B) (gr

ey)

Signal qualit

y (whit

e)

+24V (br

own)

0V (blue)

OSSD2 (y

ellow)

OSSD1 (gr

een)

Earth connection

Restart interlock active: this connection is omitted (connect S2)

Restart interlock inactive: make connection (S2 is omitted)

Legend

K1, K2: 

 Relay for processing the switching outputs OSSD 

1,OSSD 2

kn1, kn2: 

 Auxiliary contacts of the last switching relay for contac-

tor control (optional)

 

 Signals at input EDM (pin 8), only to be connected 

when the function is activated.

S1: 

Command device for external test (optional)

S2: 

Command device for restart interlock enabling

E1: 

Power supply 24 VDC ± 10%

RS 485 (A)/(B):   These connections between the transmitter and the 

receiver are required for the operation

Summary of Contents for SLC 220

Page 1: ...ct description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailin...

Page 2: ...nge 0 3 m 6 m H Range 5 m 30 m high range M Master function S Slave function Only if the information described in this operating instruc tions manual are realised correctly the safety function and the...

Page 3: ...l reset 20 ms 1 0 s signal trans mission in case of trailing edge Start interlock 250 ms 1500 ms adjustable LED indications transmitter Transmitting status restart LED indications receiver OSSD ON OSS...

Page 4: ...ton 2 8 3 Fixed blanking The SLC 220 can blank stationary parts in the protection field Multiple protection field areas can be blanked Fixed blanking area E1 R1 The range of the fixed blanking can be...

Page 5: ...nsion is possible up to max 96 lines and a pro tection field height of 2 45 m with the same resolution The connection of the systems master and slave is realised with the pre wired connector KA 0907 3...

Page 6: ...the following elements Stopping time of the machine calculation by run on time measure ment Response time of the machine and the safety light curtain and the downstream relay entire safety guard Appr...

Page 7: ...41 mm The following mounting heights to EN 999 must be observed Number of beams Mounting height above reference floor Floor in mm 2 400 900 3 300 700 1100 4 300 600 900 1200 The successor standards of...

Page 8: ...2 1289 1 8 SLC 220 E R1375 30 RFB 1375 0 8 1422 1 5 1439 2 0 SLC 220 E R1525 30 RFB 1525 0 8 1572 1 5 1589 2 0 SLC 220 E R1675 30 RFB 1675 0 8 1722 1 5 1739 2 0 All versions with resolution 30 and 80...

Page 9: ...fety light curtain safety light grid EN Accessories Mounting kit MS 1000 5 5 5 14 25 39 27 46 5 5 8 35 20 Centre support MS 1010 3 8 19 1 42 4 38 1 38 1 43 2 46 5 27 20 30 43 12 8 19 2 5 5 3 5 R 2 5 C...

Page 10: ...RS485 B grey 24V brown 0V blue RS485 A pink RS485 B grey Signal quality white 24V brown 0V blue OSSD2 yellow OSSD1 green Earth connection Restart interlock active this connection is omitted connect S2...

Page 11: ...ies Conditions For safety reasons all inspection results must be archived The operat ing principle of the SLC SLG and the machine must be known in order to be able conducting an inspection If the fitt...

Page 12: ...D OFF contactor control input must show 24V Switch on only after POWER OFF ON 1 flashes Receiver configuration error or communication error Check transmitter and receiver configuration reparameterize...

Page 13: ...manner in accordance with the national prescriptions and legislations 8 Appendix 8 1 Contact Consultancy Sales K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal...

Page 14: ...h Loss M ddinghofe 30 42279 Wuppertal Notiied body for the prototype test T V Nord Cert GmbH Langemarckstr 20 45141 Essen ID n 0044 EC prototype test certiicate n 44 205 10 555867 004 Safety Control G...

Reviews: