TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS OF LIGHT CURTAINS/LIGHT GRIDS SLC/SLG 210 RF
Protected height
160 – 1810 mm
Resolutions
20 – 30 – 40 – 50 – 90 mm
0
6 m (low)
Working range (selectable)
20, 30, 40, 50, 90mm and
Multibeam models
1
18 m
3
18 m (MASTER/SLAVE)
Safety outputs
2 PNP – 500mA / 24VDC
Response time
**
5
28 ms (see tables for specific models)
Power supply
24VDC
20%
Connections
Connectors M12 5/8-poles
Max. connection length
100 m (50 m between MASTER and SLAVE)
Operating temperature
0
55°C
Protection class
IP 65
Housing cross section
35 x 45 mm
Max. power consumption
2 W (Emitter)
3 W (Receiver)
** In case of operation of SLC / SLG 210 RF in MASTER-SLAVE configuration, the correct total SLAVE
response time must be calculated according the following formula:
t
tot_slave
= t
slave
+ t
master
+ 1,8 ms
SLC 210-E/Rxxxx-20-RF
Resolution 20 mm
0160 0310 0460 0610 0760 0910 1060 1210 1360 1510 1660 1810
Number of beams
15
30
45
60
75
90
105
120
135
150
165
180
Response time ms
7
9
10
12
14
16
18
20
22
24
26
28
Overall light curtain ht. mm
261
411
561
711
861 1011 1161 1311 1461 1611 1761 1911
SLC 210-E/Rxxxx-30-RF
Resolution 30 mm
0160 0310 0460 0610 0760 0910 1060 1210 1360 1510 1660 1810
Number of beams
8
16
24
32
40
48
56
64
72
80
88
96
Response time ms
6
7
8
9
10
11
12
13
14
15
16
17
Response time ms
MASTER/SLAVE
6
8
9
11
13
14
16
17
19
21
22
24
Overall light curtain ht. mm
261
411
561
711
861 1011 1161 1311 1461 1611 1761 1911
SLC 210-E/Rxxxx-40-RF
Resolution 40 mm
0310
0460
0610
0760
0910
1060
1210
1360
1510
1660
1810
Number of beams
10
15
20
25
30
35
40
45
50
55
60
Response time ms
6
7
7
8
9
9
10
10
11
12
12
Response time ms
MASTER/SLAVE
7
8
9
10
11
12
13
14
15
16
17
Overall light curtain ht. mm
411
561
711
861
1011 1161 1311 1461 1611 1761 1911