12
MASTER MODELS - 5 poles M12 Secondary connector.
PIN
COLOUR
NAME
TYPE
DESCRIPTION
FUNCTIONING
1
Brown
24VDC
-
+24VDC power supply
-
3
Blue
0VDC
-
0VDC power supply
-
5
Grey
PE
-
Ground connection
-
2
White
SLAVE1
INPUT
4
Black
SLAVE2
INPUT
SLAVE OSSD outputs
readout
According the normative
EN61131-2
(PNP active high)
Table 4
MASTER MODELS - 8 poles M12 Primary connector.
STANDARD MODELS - 8 poles M12 connector.
PIN
COLOUR
NAME
TYPE
DESCRIPTION
FUNCTIONING
2
Brown
24VDC
-
+24VDC power supply
-
7
Blue
0VDC
-
0VDC power supply
-
8
Red
PE
-
Ground connection
-
1
White
OSSD1
OUTPUT
3
Green
OSSD2
OUTPUT
Safety static outputs
PNP active high
5
Grey
SEL_A
INPUT
6
Pink
SEL_B
INPUT
Barrier configuration
4
Yellow
K1_K2
INPUT
External contactors
Feedback
According the normative EN61131-2
(ref. Par. "Configuration and operation
modes")
Table 5
WARNINGS REGARDING THE CONNECTION CABLES
For connections over 50 m long, use cables with a conductor cross-section
of 1 mm
2
.
The power supply to the light curtain / light grid should be kept separate from
that to other electric power equipment (electric motors, inverters, frequency
converters) or other sources of disturbance.
Connect the Emitter and the Receiver to the ground outlet.