background image

RSS260 AS

Operating instructions

Safety sensor

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC  . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.4  Actuating directions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.6  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

Functions and configuration

5.1  Programming the slave address  . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2 

Configuration of the safety monitor

  . . . . . . . . . . . . . . . . . . . . . . . . .5

5.3  Status signal "safety release"  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.4  Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5

6  Diagnostic

6.1  LED indications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.2  Error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.3  Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.4  Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.5  Read-out of the parameter port  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7  Set-up and maintenance

7.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8  Disassembly and disposal

8.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9  EU Declaration of conformity

x.000 / 03.2018 / v

.A.   -   103015221-EN / B / 2018-03-15 / 

AE-Nr

. 9043

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for RSS260 AS

Page 1: ... as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the cha...

Page 2: ...rrespond to the standard version 2 3 Comprehensive quality insurance to 2006 42 EC Schmersal is a certified company to appendix X of the Machinery Directive As a result Schmersal is entitled to autonomously conduct the conformity assessment procedure for the products listed in Appendix IV of the MD without involving a notified body The prototype test certificates are available upon request or can ...

Page 3: ...61508 PL e Control Category 4 PFH 3 93 x 10 10 h PFD 6 89 x 10 5 SIL suitable for SIL 3 applications Service life 20 years 3 Mounting 3 1 General mounting instructions During fitting the requirements of ISO 14119 must be observed The mounting holes provide for a variable mounting by means of M4 screws max tightening torque 0 8 Nm The component can be mounted in any position The minimum bend radius...

Page 4: ...sensor side 3 5 Switching distance The side allows for a maximum height misalignment X of sensor and actuator of 8 mm e g mounting tolerance or due to guard door sagging The axial misalignment Y is max 18 mm Y X Actuating curves The actuating curves represent the typical switching distance of the safety sensor during the approach of the actuator subject to the actuating direction Transverse misali...

Page 5: ...ect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 5 4 Actuator teaching actuator detection Safety sensors with standard coding are ready to use upon delivery Individually coded safety sensors and actuators will require the following teach in procedure 1 Switch the safety sensor s voltage supply off and...

Page 6: ...ng Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0 1 refer to flash code Table 2 Error messages flash codes yellow LED Flash codes yellow Designation Autonomous switch off after Error cause 4 flash pulses Ambient temperature high 0 min Ambient temperature too hig...

Page 7: ...nctionality A regular visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable 3 Remove possible metal chips Measures must be taken to protect against manipulation or against the bypassing of safety device for example using an extra actuator Damaged or defectiv...

Page 8: ...t Directives Machinery Directive RED Directive RoHS Directive 2006 42 EC 2014 53 EU 2011 65 EU Applied standards EN 60947 5 3 2013 EN 300 330 V2 1 1 2017 ISO 14119 2013 EN ISO 13849 1 2008 AC 2009 IEC 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5...