schmersal RSS260 AS Operating Instructions Manual Download Page 8

8

EN

RSS260AS-C-EN

Operating instructions

Safety sensor

RSS260 AS

9.  EU Declaration of conformity

Place and date of issue:

Wuppertal, May 26, 2017

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Name of the component:

RSS260-AS

Type:

See ordering code

Description of the component:

Non-contact safety sensor with  

integrated AS-i Safety at Work

Relevant Directives:

Machinery Directive

RED-Directive

RoHS-Directive

2006/42/EC

2014/53/EU

2011/65/EU

Applied standards:

EN 60947-5-3:2013,

EN 300 330 V2.1.1:2017,

ISO 14119:2013,

EN ISO 13849-1:2008 + AC:2009,

IEC 61508 parts 1-7:2010,

EN 62061:2005 + AC:2010 + A1:2013

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Alboinstr. 56, 12103 Berlin

ID n°: 0035

EC-prototype test certificate:

01/205/5348.02/15

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Summary of Contents for RSS260 AS

Page 1: ... as part of an entire plant or machine It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the cha...

Page 2: ...rrespond to the standard version 2 3 Comprehensive quality insurance to 2006 42 EC Schmersal is a certified company to appendix X of the Machinery Directive As a result Schmersal is entitled to autonomously conduct the conformity assessment procedure for the products listed in Appendix IV of the MD without involving a notified body The prototype test certificates are available upon request or can ...

Page 3: ...61508 PL e Control Category 4 PFH 3 93 x 10 10 h PFD 6 89 x 10 5 SIL suitable for SIL 3 applications Service life 20 years 3 Mounting 3 1 General mounting instructions During fitting the requirements of ISO 14119 must be observed The mounting holes provide for a variable mounting by means of M4 screws max tightening torque 0 8 Nm The component can be mounted in any position The minimum bend radius...

Page 4: ...sensor side 3 5 Switching distance The side allows for a maximum height misalignment X of sensor and actuator of 8 mm e g mounting tolerance or due to guard door sagging The axial misalignment Y is max 18 mm Y X Actuating curves The actuating curves represent the typical switching distance of the safety sensor during the approach of the actuator subject to the actuating direction Transverse misali...

Page 5: ...ect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs in the control system 5 4 Actuator teaching actuator detection Safety sensors with standard coding are ready to use upon delivery Individually coded safety sensors and actuators will require the following teach in procedure 1 Switch the safety sensor s voltage supply off and...

Page 6: ...ng Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0 1 refer to flash code Table 2 Error messages flash codes yellow LED Flash codes yellow Designation Autonomous switch off after Error cause 4 flash pulses Ambient temperature high 0 min Ambient temperature too hig...

Page 7: ...nctionality A regular visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable 3 Remove possible metal chips Measures must be taken to protect against manipulation or against the bypassing of safety device for example using an extra actuator Damaged or defectiv...

Page 8: ...t Directives Machinery Directive RED Directive RoHS Directive 2006 42 EC 2014 53 EU 2011 65 EU Applied standards EN 60947 5 3 2013 EN 300 330 V2 1 1 2017 ISO 14119 2013 EN ISO 13849 1 2008 AC 2009 IEC 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1 2013 Notified body for the prototype test TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5...