schmersal MZM 120 Operating Instructions Manual Download Page 1

MZM 120

Operating instructions

Safety switch with interlocking function

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete  

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operat-

ing instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards  

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

Failure to comply with this warning notice could 

lead to failures or malfunctions. 

Warning:

Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed 

to execute safety-related functions as part of an entire plant or machine.  

It is the responsibility of the manufacturer of a machine or plant to 

ensure the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 

versions listed below or for the applications authorised by the manufac-

turer. Detailed information regarding the range of applications can be 

found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-

tions manual, labelled with the caution or warning symbol above, the 

country-specific installation standards as well as all prevailing safety 

regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is  

provided without liability and is subject to technical modifications.

The entire concept of the control system, in which the  

safety component is integrated, must be validated to  

EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC . . . . . . . . . . . . . .2

2.4  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6  Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

5   Operating principles and latching force adjustment

5.1  Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .4

6  Diagnostic functions

6.1  Diagnostic LED's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Safety switch with conventional diagnostic output. . . . . . . . . . . . . .5

6.3  Safety switch with serial diagnostic function . . . . . . . . . . . . . . . . . .6

7  Set-up and maintenance

7.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8   Disassembly and disposal

8.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9  Appendix

9.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9.2  Wiring coniguration and connector accessories . . . . . . . . . . . . . . .8

9.3  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

x.

00

/ J

an

ua

r 2

01

/ v

.A

. -

 1

01

21

65

37

-E

N

 / 

/ 2

01

2-

01

-1

/ -

EN

Operating instructions. . . . . . . . . . . .pages 1 to 10

Translation of the original operating instructions

Summary of Contents for MZM 120

Page 1: ...nd in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual labelled with the caution or warning symbol above the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be found in the Schmersal catalogues or in...

Page 2: ...dition of the safety outputs for as long as the safety guard is open The opening of the safety guard is detected by the safety sensors The magnetic force monitoring detects when the latching force drops below a defined latching force The MZM 120 distinguishes between a low holding force which pre vents the safety guard from inadvertedly bursting open and a latching force F which prevent inadverten...

Page 3: ...ervice life 20 years Classification PDF M 3 Mounting 3 1 General mounting instructions For fitting the MZM 120 safety switch and the actuator two mounting holes for M6 screws with washers washers included in delivery are provided The safety switch must be used as end stop For a safe operation of the system the angle between the safety switch and the actuator compulsory must be 2 After fitting the ...

Page 4: ...utputs are re enabled The latching force F is permanently measured and checked In this way soiling of the solenoid interlock can be detected If the latching force drops below 300 N the release signal for the safety outputs Y1 and Y2 is not given Description of the MZM 120 latching force adjustment The latching force of the MZM 120 can be set in 8 steps each within a range of approx 30 N to approx ...

Page 5: ...r 30 minutes The safety outputs initially remain enabled This enables the shutdown of the process in a controlled manner An error warning is deleted when the error cause is eliminated Behaviour of the diagnostic outputs of the W variant Input signal magnet control IN Normal sequence door was locked OUT Door could not be locked or fault OUT Legend Safety guard open Safety guard closed unlock guard ...

Page 6: ... fault has occured which causes the safety outputs to be disabled The fault is reset when the cause is eliminated and bit 7 of the request byte changes from 1 to 0 or the safety guard is opened Faults at the safety outputs are only deleted upon the next release as the fault recti fication cannot be detected sooner If more than one fault is detected at the safety outputs the component will be elect...

Page 7: ...ck max angular misalignment see Mounting part 3 Check the integrity of the cable entry and connections 4 Check the switch enclosure for damage 5 Remove particles of dust and soiling 7 2 Maintenance In the case of correct installation and adequate use the safety compo nent features maintenance free functionality We recommend a regular visual inspection and functional test including the following st...

Page 8: ...s in series Safety outputs evaluation Field bus 24 VDC GND 1 2 3 5 4 6 8 X1 Y1 X2 SD IN SD OUT A1 A2 1 2 3 5 4 6 8 X1 Y1 X2 7 Y2 7 Y2 SD IN SD OUT A1 A2 X1 Y1 X2 Y2 SD IN SD OUT Y1 Y2 SD IN 9 2 Wiring configuration and connector accessories Function safety switchgear Pin configuration of the connector Colour code or conductor numbering of the below mentioned Schmersal connectors Possible colour co...

Page 9: ...e technical documentation Ulrich Loss Möddinghofe 30 42279 Wuppertal Notiied body which approved the full quality assurance system referred to in Appendix X 2006 42 EC TÜV Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 Place and date of issue Wuppertal November 29 2011 Authorised signature Philip Schmersal Managing Director EC Declaration of conformity Translation of the orig...

Page 10: ...H Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...