14
Operating instructions
Solenoid interlock
AZM40
EN
3. Mounting
3.1 General mounting instructions
Please observe the relevant requirements of the standards
EN ISO 12100, EN ISO 14119 and EN ISO 14120.
Any mounting position.
The solenoid interlock must not be used as an end stop.
For the correct fixing of the solenoid interlock, the device is provided
with two mounting holes for M5 screws.
The M5 screws should have at least the strength class 8.8.
The minimum tightening torque of the M5 screws is 4 Nm.
The locking bolt in the safety interlock is self-lubricating.
This grease must not be removed.
The accumulation of fine-grained dirt in the bolt area must
be avoided. Consequently, we do not recommend installing
the interlock in a position where the locking bolt is retracted
upwards from below.
The actuator must be installed in such a way that it is pro-
tected from damage by external influences.
The interlock with locking bolt (A) and actuator with
triangular marking (B) must be installed in the same
installation direction.
A
B
The actuator must be permanently fitted to the safety
guards and protected against displacement by suitable
measures (tamperproof screws, gluing, drilling, pinning).
Authorised actuator and interlock offset
Tilt angle
Rotation angle
2°
-+
2°
-+
The AZM40 can be operated
within the following tolerance limits:
X axis: ± 2 mm
Y axis: ± 1 mm
Z axis: ± 1.5 mm (actuator in centre position)
Z
Y
X
Adjustment
The two hexagon socket screws M4 can be used to adjust the actuator
tongue in the X direction, using a hexagonal key wrench AF 2 mm.
Adjustment via hexagon socket screws M4
The hexagon socket screws must not be completely
unscrewed.
Actuation directions
The actuator can be continuously inserted by 180°.