2
Operating instructions
Solenoid interlock
AZM 415-22
AZM 415-33
EN
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZM 415-22ZPK
➀
-M20 24 VAC/DC
No. Option
Description
➀
Power to unlock
A
Power to lock
AZM 415-33ZPDK
➀➁
➂➃
➄
No. Option
Description
➀
Power to unlock
A
Power to lock
➁
ST
M23 connector at the right-hand side
STL
M23 connector at the left-hand side
➂
without manual release
E
Manual release using triangular key
(only for power to unlock principle)
➃
1637
gold-plated contacts
➄
24 VAC / DC
U
s
24 VAC
110 VAC
U
s
110 VAC
230 VAC
U
s
230 VAC
Only if the information described in this operating instructions
manual are realised correctly, the safety function and
therefore the compliance with the Machinery Directive is
maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Purpose
The AZM 415 solenoid interlock has been designed to prevent movable
safety guards, e.g. fences, covers or doors, in conjunction with the
control part of a machine, e.g. fail-safe delay timers or fail-safe standstill
monitors, from being opened before hazardous conditions (e.g. run-on
mouvements) have been eliminated. The AZM 415-33 includes three
switch inserts and is designed for monitoring double safety guards.
Interlocks with power to lock principle may only be used in
special cases after a thorough evaluation of the accident risk,
since the safety guard can be opened immediately on failure
of the power supply or upon activation of the main switch.
The safety switchgears are classified according to
ISO 14119 as type 2 interlocking devices.
Solenoid interlock with manual release AZM 415-33PDKE
The manual release is only used with components that operate on the
power to unlock principle. It is used as a mounting tool and also as a
tool to open a closed and locked safety guard in case of a power failure.
The point of access to the manual release or the manual release itself
must be protected in accordance with the provisions of the professional
association, e.g. by sealing during mounting.
Unlocking:
using triangular key (available as accessory)
Reset:
by turning the triangular key back
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards:
IEC 60947-5-1, ISO 14119
Enclosure:
light-alloy die-cast, enamel finish
Actuator and locking bolt:
zinc-plated metal / aluminium
Locking force F:
- AZM 415-22:
3,500 N
- AZM 415-33:
2,500 N (each safety guard)
Latching force:
150 ... 400 N (adjustable)
Coding level according to ISO 14119:
low
Ambient temperature:
−25 °C … + 50 °C
Protection class:
IP67
Degree of pollution:
3
Positive break travel (unlocked):
AZM 415-22: 5 mm
AZM 415-33: 4,5 mm
Positive break force (unlocked):
min. 15 N (depending on
the setting of the ball latch)
Actuating speed:
max. 0.2 m/s
Max. actuating frequency:
2,000 s/h
Mechanical life:
> 1,000,000 operations
Contact material:
Silver
Contact types:
Change-over contact with double break, type Zb
or 2 NC contacts, with galvanically
separated contact bridges
Switching system:
A
IEC 60947-5-1; slow action, NC contact with
positive break
Connection:
screw terminals
Cable type:
rigid / flexible
Cable section:
min. 0.75 mm² - max. 2.5 mm²
(including conductor ferrules)
Cable entry:
2 x M20 x 1.5
Electrical data:
Utilisation category:
AC-15
Rated operating current/voltage I
e
/U
e
:
4 A / 230 VAC
Rated impulse withstand voltage U
imp
:
4 kV
Rated insulation voltage U
i
:
250 V
Thermal test current I
the
:
6 A
Max. fuse rating:
6 A gG D-fuse
Required rated short-circuit current:
1,000 A
Magnet switch-on time:
100 %
Rated control voltage U
s
:
24 VAC / DC,
110 VAC, 50 / 60 Hz,
230 VAC, 50 / 60 Hz,
Power consumption:
max. 10 W