1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

Content

About this document

1.1  Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

  . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used. . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC . . . . . . . . . . . . .2

2.4  Destination and use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  General mounting instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Manual release  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Electrical connection

4.1  General information for electrical connection  . . . . . . . . . . . . . . . .4

Operating principle and diagnostic functions

5.1  Magnet control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

5.2  Mode of operation of the safety outputs  . . . . . . . . . . . . . . . . . . . .4

Diagnostic functions

6.1  Diagnostic LED's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6.2  Solenoid interlock with conventional diagnostic output . . . . . . . . .5

6.3  Solenoid interlock with serial diagnostic function  . . . . . . . . . . . . .6

Set-up and maintenance

7.1  Functional testing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Disassembly and disposal

8.1  Disassembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8.2  Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Appendix

9.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

9.2 

Wiring configuration and accessories

 . . . . . . . . . . . . . . . . . . . . . .9

10  EU Declaration of conformity

x.000 / 05.2017 / v

.A.   -   101

178802-EN / R / 2017-03-28 / 

AE-Nr

. 7307

EN

Operating instructions. . . . . . . . . . . .pages 1 to 10

Original

Summary of Contents for AZM 200

Page 1: ...e with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations an...

Page 2: ...0 with non contact electronic safety sensors is designed for application in safety circuits and is used for monitoring the position of movable safety guards The safety function consists of safely switching off the safety outputs when the safety guard is unlocked or opened and maintaining the safe switched off condition of the safety outputs for as long as the safety guard is open For applications ...

Page 3: ... 10 9 h PFD 2 2 x 10 4 SIL suitable for SIL 2 applications Service life 20 years The safety consideration of the guard locking function only applies for standard devices with monitored solenoid interlock AZM 200 1P2P W see Ordering code The actuation of the interlock must be compared with the external OSSD enabler If a shut down now occurs due to an unintentional unlocking this is detected by an e...

Page 4: ...or is connected to electronic safety monitoring modules we recommend that you set a discrepancy time of 100 ms The safety inputs of the safety monitoring module must be able to blank a test impulse of approx 1 ms The safety monitoring module does not need to have a cross wire short monitoring function if necessary the cross wire short monitoring function must be disabled Information for the select...

Page 5: ...or The safety outputs enable and allow a restart An interlocking chain must be permanently locked to enable the reactivation If more than one fault is detected at the safety outputs or a cross circuit is detected between Y1 and Y2 the solenoid interlock will be electronically locked and a normal fault reset will no longer be possible To reset this type of interlocking the solenoid interlock must b...

Page 6: ...id interlocks can be wired in series For the evaluation of the serial diagnostics line either the PROFIBUS Gateway SD I DP V0 2 or the Universal Gateway SD I U are used This serial diagnostic interface is integrated as a slave in an existing field bus system In this way the diagnostic signals can be evaluated by means of a PLC The response data and the diagnostic data are automatically and permane...

Page 7: ...it 1 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Fitting of the solenoid interlock and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 7 2 Maintenance We recommend a regular visual inspection and functional test ...

Page 8: ...ge must be removed from all components up to the last component The voltage is supplied at both safety inputs of the terminal safety component of the chain considered from the safety monitoring module The safety outputs of the first safety component are wired to the safety monitoring module X1 Y1 X2 Y2 1 2 3 5 6 8 X1 X2 24V GND Y1 Y2 1 2 3 5 6 8 X1 4 Y1 4 Y1 X2 7 Y2 7 Y2 OUT 24V GND OUT SPS PLC IN...

Page 9: ... IN Solenoid control SD input 8 4 RD OR without function 9 6 Connector plug ST1 M23 8 1 pole Connector plug ST2 M12 8 pole 1 2 9 3 4 5 6 7 8 5 8 4 3 2 1 7 6 Connecting cables with coupling female IP67 M23 8 1 pole 8 x 0 75 mm Connecting cables with coupling female IP67 IP69 M12 8 pole 8 x 0 23 mm to DIN 47100 Cable length Part number Cable length Part number 5 0 m 10 0 m 101209959 101209958 2 5 m ...

Page 10: ...onform to the applicable European Directives Name of the component AZM 200 Type See ordering code Description of the component Interlocking device with electromagnetic inter lock for safety functions Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards EN 60947 5 1 2004 AC 2005 A1 2009 EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 ...