Operating instructions

Safety switch

AZ 415-33ZPK

EN

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of the 

safety switchgear, personal hazards or damage to machinery 

or plant components cannot be excluded. The relevant requi-

rements of the standard EN 1088 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages resul-

ting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

AZ 415-33ZPK-

No.

Option

Description

1637

Gold-plated contacts

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefo-

re the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

Safety switches with separate actuators are suitable for movable safety 

guards, which need to be closed to ensure the necessary operational 

security.

The safety switches are used for applications, in which the hazardous 

situation is terminated without delay when the safety guard is opened.

Operating principle

By closing the safety guard, switch insert S1 and S3 are released and 

switch insert S2 actuated (differentiated operating principle). When the 

actuator is fully inserted, the safety guard is not subject to any ejection 

force.

When the safety guard is opened, the NC contacts are positively ope-

ned and the NO contacts are closed.

The user must evaluate and design the safety chain in 

 accordance with the relevant standards and on the required 

safety level.

2.4  Technical data

Standards

IEC/EN 60947-5-1, BG-GS-ET-15

Enclosure:

 

light-alloy die-cast, enamel finish

Protection class:

 

IP67 to IEC/EN 60529 / DIN VDE 0470-1

Contact material:

 

Silver

Contact type:

 

Change-over with double break Zb, galvanically 

separated contact bridges

Switching system:

 

A

 IEC 60947-5-1 slow action, 

NC contact with positive break

Connection:

 

screw terminals

Cable type:

 

solid and stranded wire

Cable section:

 

0,75 … 1,5 mm

2

 

(incl. conductor ferrules)

Cable entry:

 

2 × M20 × 1.5

U

imp

:

 

4 kV

U

i

:

 

250 V

I

the

:

 

6 A

Required short-circuit current:

 

1000 A

Utilisation category:

 

AC-15, DC-13

l

e

/U

e

:

 

4 A / 230 VAC

4 A / 24 VDC

Max. fuse rating:

 

6 A gG D-fuse

Positive break travel:

 

4.5 mm

Positive break force:

 

15 N (depending on the setting of the ball latch)

Ambient temperature:

 

−25 °C … +80 °C

Latching force:

 

80 … 400 N (adjustable)

Mechanical life:

 

> 10

6

 operations

Actuating speed

max. 0.2 m/s

Max. switching frequency:

 

2000/h

2.5  Safety classification

Standards:

 

EN ISO 13849-1

B

10d

 (NC contact):

 

2.000.000

B

10d 

(NO contact) at 10% ohmic contact load: 

1.000.000

Mission time:

 

20 years

MTTF

B

d x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific parame-

ters h

op

, d

op

 and t

cycle

 as well as the load.)

3.  Mounting

3.1  General mounting instructions

The mounting holes are accessible after removal of the cover. The 

switch enclosure must not be used as an end stop. Any mounting positi-

on. The mounting position however must be chosen so that the ingress 

of dirt and soiling in the used opening is avoided.

Mounting of the actuators: 

See mounting instructions actuators.

Please observe the remarks of the standards EN ISO 12100, 

EN 953 and EN 1088.

Summary of Contents for AZ 415-33ZPK

Page 1: ...sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selec tion mounting and integrat...

Page 2: ...eleased and switch insert S2 actuated differentiated operating principle When the actuator is fully inserted the safety guard is not subject to any ejection force When the safety guard is opened the NC contacts are positively ope ned and the NO contacts are closed The user must evaluate and design the safety chain in accordance with the relevant standards and on the required safety level 2 4 Techn...

Page 3: ...wiring compartment Maximum tightening torque for the screws cover 0 6 0 1 Nm bottom cover 0 7 0 1 Nm The conductors of the connecting cables must not obstruct the movement of the switching lever 4 2 Contact variants Contacts are shown with safety guard closed 23 21 11 13 31 33 24 22 12 14 32 34 S2 S1 S3 Legend P actuated Q not actuated A Positive break NC contact 5 Set up and maintenance 5 1 Funct...

Page 4: ...ty K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal 11 May 2009 Authorised signature Heinz Schmersal Managing Director EC Declaration of conformity Translation of the original ...

Reviews: