schmersal AZ 415-33ZPK Operating Instructions Download Page 4

4

Operating instructions

Safety switch

AZ 415-33ZPK

EN

AZ 415-B-EN

The currently valid declaration of conformity can be down-

loaded from the internet at www.schmersal.net.

Name of the safety component:

AZ 415

Description of the safety component:

Positive break position switch with separate 

actuator for safety functions

Harmonised EC-Directives:

2006/42/EC-EC-Machinery Directive

Person authorized for the compilation  

of the technical dokumentation:

Ulrich Loss

Möddinghofe 30

42279 Wuppertal

7.  Appendix

7.1  EC Declaration of conformity

K. A. Schmersal GmbH

Industrielle Sicherheitsschaltsysteme

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Telefon  +49 - (0)2 02 - 64 74 - 0 

Telefax  +49 - (0)2 02 - 64 74 - 1 00

E-Mail:   [email protected]

Internet:   http://www.schmersal.com

Place and date of issue:

Wuppertal, 11. May 2009

Authorised signature

Heinz Schmersal

Managing Director

EC Declaration of conformity

Translation of the original declaration  

of conformity

valid as of December 29, 2009

K.A. Schmersal GmbH

Industrielle Sicherheitsschaltsysteme

Möddinghofe 30, 42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described safety components both in its basic design and const-

ruction conform to the applicable European Directives.

Summary of Contents for AZ 415-33ZPK

Page 1: ...sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selec tion mounting and integrat...

Page 2: ...eleased and switch insert S2 actuated differentiated operating principle When the actuator is fully inserted the safety guard is not subject to any ejection force When the safety guard is opened the NC contacts are positively ope ned and the NO contacts are closed The user must evaluate and design the safety chain in accordance with the relevant standards and on the required safety level 2 4 Techn...

Page 3: ...wiring compartment Maximum tightening torque for the screws cover 0 6 0 1 Nm bottom cover 0 7 0 1 Nm The conductors of the connecting cables must not obstruct the movement of the switching lever 4 2 Contact variants Contacts are shown with safety guard closed 23 21 11 13 31 33 24 22 12 14 32 34 S2 S1 S3 Legend P actuated Q not actuated A Positive break NC contact 5 Set up and maintenance 5 1 Funct...

Page 4: ...ty K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal 11 May 2009 Authorised signature Heinz Schmersal Managing Director EC Declaration of conformity Translation of the original ...

Reviews: