S
CHMALZ
SCP
I
/
SMP
I
2-7
Electrical connection
The electrical connection of the ejector is made using 8-pin M12 male connector. The pin
assignment is described in the “Technical data” chapter.
The plug connectors may not be connected or disconnected when the system is live.
The ejector may only be operated via power supply units with protected extra-low volt-
age (PELV). The system must incorporate safe electrical cut-off of the power supply in
compliance with EN60204.
The power supply, signal inputs and signal outputs have a maximum line length of 30
metres.
Pneumatic connection
Use only well maintained compressed air (air or neutral gas according to EN 983, filtered
40 µm, oiled or unoiled).
High quality compressed air is important for the prolonged service life of the ejector.
Dirt particles or foreign bodies in the ejector connections, hoses or pipelines can lead to
partial or complete ejector malfunction.
Hoses and pipelines should be laid as short as possible.
Insufficient compressed air is supplied if the internal diameter on the compressed air
side is too small. This prevents the ejector from performing as specified in its defined
performance data.
Excessive flow resistance occurs if the internal diameter on the vacuum side is too small.
This leads to both a reduction in suction power and increased suction times. Blow-off
times are also lengthened.
Hose lines must be laid without bends and crimps.
Only use the hose or pipe internal diameters recommended for the ejector. If this is not
possible, use the next largest internal diameter.
Line cross-section internal diameter
1)
Compressed air side
Vacuum side
8 mm
9 mm
1)
Based on a maximum hose length of 2 m