Cycle counters [ct1] and [ct2]
The ejector is equipped with two counters. Counter 1 is increased with each valid pulse on
the suction signal input, and therefore counts the number of suction cycles in automatic
mode. Counter 2 is increased with each switch of the suction valve. The switching frequen-
cy of the air-saving function can then be determined from the difference between counters 1
and 2.
Symbol
Function
Description
Counter 1
Counter for suction cycles
(suction signal input)
Counter 2
Counter for valve switching frequency
Displaying the cycle counters
The cycle counters are displayed as follows:
Press and hold the
and
buttons together for more than 3 seconds.
Enter a valid PIN if the menu is locked.
Select the desired
[ct1]
or
[ct2]
counter using the
or
buttons.
Confirm by pressing the
button.
The final three decimal points of the complete counter value are displayed. The decimal
point at the far right flashes. This corresponds to the three-digit block with the lowest per-
ceived value.
The remaining decimal points of the complete counter value can be displayed using the
or
buttons. The decimal points show which three-digit block of the complete counter
value is shown in the display.
The complete counter value is comprised of the three digit blocks together:
Displayed position
10
6
10
3
10
0
Digit block
The current complete counter value in this example is 48 618 593.
Exit the counter function using the
button.