S
CHMALZ
SCPS
6-26
S
PARE AND WEARING PARTS
Type
Designation
Article no.
Legend
Silencer insert
10.02.02.04141
W
Filter
10.02.02.03376
S
Insulating plate
10.02.02.04152
W
When tightening the securing screws on the silencer module, observe the maxi-
mum tightening torque of 0,5 Nm.
When you replace the silencer insert, we recommend that you also replace the
insulating plate.
T
ROUBLESHOOTING
Fault
Possible cause
Solution
Vacuum level is
not reach or vacu-
um is created too
slowly
Press-in screen contaminated
Replace the screen
Silencer is dirty
Replace silencer
Leakage in hose line
Check hose connections
Leakage at suction pad
Check suction pad
Operating pressure too low
Increase operating pressure (observe
max. limits)
Internal diameter of hose lines too
small
See recommended hose diameters
Payload cannot be
held securely
Vacuum level too low
Increase the control range if the air-
saving function is activated
Suction pad too small
Select a larger suction pad