S
CHMALZ
SCPS
3-15
G
ENERAL FUNCTIONS
M
ANUAL MODE
The output signals may change during set-up in manual mode.
Ensure that the machine or system does not start moving as a result.
Personal injury or damage to the ejector could result.
Starting manual mode always switches the ejector to “pneumatically OFF” mode.
In other words, starting manual mode interrupts an active suction process.
Danger due to falling parts.
In manual mode, the pick-up and blow-off ejector functions can be controlled independently
of the higher-level controller using the buttons on the operating panel.
In this operating mode, the H1 and H2 LEDs both flash.
A
CTIVATING MANUAL MODE
Activate manual mode as follows:
Press and hold the
and
buttons together for more than 3 seconds
M
ANUAL SUCTION
In manual mode, suction is activated by pressing the
button. Exit suction mode by
pressing the
button again or by pressing the
button.
If the air-saving function is activated this is also activated in manual mode.
M
ANUAL BLOW
-
OFF
Blow-off mode is activated in manual mode by pressing the
button. This mode remains
active as long as the button is pressed.
D
EACTIVATING MANUAL MODE
Exit manual mode using the button.
The ejector also exits manual mode when the statuses of the external signal inputs change.
This automatic exiting of manual mode due to changes in external signals can
cause the object being handled to move (due to suction or blow-off).