 CAUTION

Noise pollution due to incorrect installation of the pressure and vacuum connections

Hearing damage

4

Correct installation.

4

Wear ear protectors.

7.1  Connecting the Compressed Air and Vacuum

4

Connect the compressed air hose to the connection
(1).
Connect the vacuum hose to the connection (2). 
For threaded connectors, the maximum tightening
torque is 1 Nm.

1

2

8  Electrical Connection

NOTE

Change of output signals when product is switched on or plug is connected

Personal injury or damage to property

4

Electrical connection may be performed only by specialists who can evaluate the effects of sig-
nal changes on the overall system.

NOTE

Incorrect power supply

Destruction of the integrated electronics

4

Operate the product using a power supply unit with protected extra-low voltage (PELV).

4

The system must incorporate safe electrical cut-off of the power supply in compliance with
EN60204.

4

Do not connect or disconnect the connector under tension and/or when voltage is applied.

The electrical connection supplies the ejector with power and communicates with the controller of the higher-level
machine using defined outputs.