![Schmalz SCPMc Series Short Instruction Manual Download Page 4](http://html1.mh-extra.com/html/schmalz/scpmc-series/scpmc-series_short-instruction-manual_1212882004.webp)
4. Press the
button to save the modified value.
ð
The first digit is accepted and the second digit flashes.
5. Use the
button to set the second digit.
6. Press the
button to save the modified value.
ð
The second digit is accepted and the third digit flashes.
7. Use the
button to set the third digit.
8. Press the
button to save the modified value.
ð
If the value entered lies within the permissible value range, it is accepted and the modified parameter is dis-
played.
ð
If the entered value does not lie within the permissible value range, this is briefly indicated on the display
[
1nc
] and the new value is not accepted.
If input is interrupted for longer than 1 minute or if no input is made, the display automatically switches to the
measurement display.
5 Checking the Delivery
The scope of delivery can be found in the order confirmation. The weights and dimensions are listed in the delivery
notes.
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing.
2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier
and J. Schmalz GmbH.
6 Installation Instructions
CAUTION
Improper installation or maintenance
Personal injury or damage to property
4
During installation and maintenance, make sure that the ejector is disconnected and depressur-
ized and that it cannot be switched on again without authorization.
For safe installation, the following instructions must be observed:
1. Use only the connections, mounting holes and attachment materials that have been provided.
2. Carry out mounting and removal only when the device is in an idle, depressurized state.
3. Pneumatic and electrical line connections must be securely connected and attached to the ejector.
7 Pneumatic Connection
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4
Wear eye protection
4
Do not look into compressed air openings
4
Do not look into the silencer air stream
4
Do not look into vacuum openings, e.g. suction cups
4 / 6
EN-US · 30.30.01.02085 · 00 · 06/19