3 Product Description
10 / 36
EN-US · 30.30.00.00422 · 08 · 09/22
3 Product Description
3.1 Ejector Designation
The breakdown of the item designation (e.g. SCPS 10 M G02 NO M12-5 PNP) is as follows:
Property
Variants
Type of ejector
SCPS
Performance class
07, 10, 15
Power blow-off function
M
Pneumatic connection
G02 (1/8" internal thread)
Control unit
Normally open (NO)
Normally closed (NC)
Electrical connection
M12 (1 x M12, 5-pin)
Signal inputs and outputs
NPN, PNP
3.2 Ejector Structure
3
1
4
5
6
8
2
7
9
10
1
Blow off valve screw
6
1/8" compressed air connection (marking 1 [P])
2
1/8" vacuum connection; marking 2 [V]
7
Silencer cover
3
Display and operating element
8
Mounting hole (2x)
4
M12 electrical connection
9
Exhaust outlet (marking 3)
5
Control unit
10
Power blow-off module for variant M