2. Pressure sensor setting
1. Press
or
button at "Function Setting
Mode" to display [
F-01
] [
ovt1
].
2. Press
button to switch to "Sensor Selec-
tion" (
oVt1
- selected output).
3. Press
or
button to select pressure
sensor of OUT 1.
4. Press
button to switch to "Output Mode
Setting"
5. Press
or
button to select output
mode of OUT1 (3 output modes included).
XY5
= Hysteresis Mode
= Window Comparator Mode
op5
= One Point Set Mode
6. Press
button to switch to "Output Type
Setting".
7. Press
or
button to select OUT1 type.
no
= NO mode (normally open mode)
nc
= NC mode (normally close mode)
NOTE: Type setting will not display when Ac-
cumulated Pulse Output Mode is set.
8. Press
button to switch "Set Value Setting".
9. Press
or
button to adjust the set
value.
Hysteresis Mode [
xy5
]: [
l-1
] and [
x -1
]
Window Comparator Mode [
]: [
l-1
]
and [
x -1
]
One Point Set Mode [
op5
]: [
P -1
]
10. Press
button to switch to "Fixed Hysteresis
Setting".
11. Press
or
button to adjust fixed hys-
teresis value.
NOTE: Fixed hysteresis setting will not display
when Hysteresis Mode is set.
12. Press
button to return to "Function Selec-
tion Mode".