Operating and Menu Concept
EN-US · 30.30.01.01963 · 01 · 09/21
19 / 52
3. Use the
button to change the value. The value increases by 1 each time that the button is
pressed. After 9, the counter goes back to 0 when the
button is pressed.
4. Press the
button to save the modified value.
ð
The first digit is accepted and the second digit flashes.
5. Use the
button to set the second digit.
6. Press the
button to save the modified value.
ð
The second digit is accepted and the third digit flashes.
7. Use the
button to set the third digit.
8. Press the
button to save the modified value.
ð
If the entered value is within the permissible value range, it is accepted and the modified parameter
is displayed.
ð
If the entered value is not within the permissible value range, this is briefly indicated on the display
[
1nc
] and the new value is not accepted.
If input is interrupted for longer than 1 minute or if no input is made, the measurement screen is auto-
matically displayed.
5.3 Extended Functions menu (EF)
An “Extended Functions” menu (EF) is available for applications with special requirements.
5.3.1 Functions in the Extended Functions menu (EF)
The following table shows an overview of the display codes and parameters in the “Extended Functions”
menu:
Display
code
Parameter
Possible settings
Explanation
ctr
Energy-saving
function
oFF
on
Control function off
Control active
-L-
Max. permissi-
ble leakage
Values config-
urable between
0
and
999
Permitted leakage
Unit: millibar per second
t-1
Max. permissi-
ble evacuation
time
configurable be-
tween 0.01 and
9.99 seconds in
steps of 0.01
off
Permitted evacuation time
No monitoring
uni
Vacuum unit
bAr
k
PA
iX9
P5i
Define the displayed vacuum unit
Vacuum level in millibar [mbar]
Vacuum level in kilopascal [kPa]
Vacuum value in inch of mercury [inHg]
Vacuum value in pound-force per square inch [psi]
rE5
Reset
No
YE5
The values remain unchanged
Reset parameter values to factory settings