Operating and Menu Concept
EN-US · 30.30.01.01963 · 01 · 09/21
17 / 52
5 Operating and Menu Concept
The mini compact ejector is operated using two buttons on the foil keypad:
MENU BUTTON
PLUS BUTTON
The following information can be shown on the display:
•
The current vacuum measurement value
•
The selected menu item
•
The settings
•
Error messages in the form of error codes
The operating menu’s home screen shows the currently measured vacuum level in the selected display
unit. Millibar is fixed as the unit. The measured value is displayed as positive compared to the ambient air
pressure.
5.1 Button Assignments in Display Mode
5.1.1 Opening the Menu
Press the
PLUS BUTTON
to open the menus as follows:
4
Press the
button briefly.
ð
The main menu opens with the first parameter [
5P1
].
Opening the EF menu for extended functions:
1. Press the
button several times until the parameter
EF
appears on the display.
2. Press the
button to switch to the EF submenu for extended functions.
ð
The EF menu opens with the first parameter [
ctr
].
Opening the INF menu:
1. Press the
button several times until the parameter
1mF
appears on the display.
2. Press the
button to switch to the INF submenu for information.
ð
The INF menu opens with the first parameter [
cc1
].
5.1.2 Displaying the Basic Settings (Slide Show)
When you press the
button from the home screen, the following parameters are automatically dis-
played one after the other on the display (slide show):
•
The vacuum unit
•
The value of switching point SP1
•
The value of reset point rP1
•
The value of switching point SP2
•
The supply voltage US
The display cycle returns to the vacuum display after a complete cycle or can be canceled at any time by
pressing any button.