OPERATOR'S MANUAL
16
Subject to technical changes
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
LuchsNT
Version: 27142-A.1
4.6 External
sensor
button via converter box 3.0
Sensor buttons connected to the converter box (optional accessory) behave in the same
way as the ON/OFF sensor buttons connected to the control unit. The total of four
possible buttons are OR-linked to each other. When a sensor button is confirmed, all
connected sensor buttons give visual feedback, provided they are illuminated.
The button lighting lights up when the spotlights are ON and light up.
It is unlit when spotlights are OFF.
The LEDs go out during the blocking time.
In the connected converter box, the LED display and digital outputs DOUT1 to DOUT3
show the following status of the switch box:
DOUT4 is switched when spotlights are switched on.
The status of the digital outputs DOUT1 to DOUT3 is displayed via the green LEDs in
the converter box. The output is then active when the green LED lights up.
Connection cable
4 x 0.5 mm² max. 30 m
BUS control line
Power supply voltage
Sensor button 1-3
Lit 1x
Rotary switch
Mode A