SECT
| V1 | INSTALLATION MANUAL | 202102
13
SCHLETTER SOLAR GMBH | SUBJECT TO CHANGES
6.2. Cable trays on a concrete roof
Cable trays can be installed on a concrete roof by fixing to a row of concrete sole plates,
300 mm diameter x 100 mm high. The sole plates can be spaced up to 1200 mm apart. A sole
plate can support a join between two sections of cable tray. Fasteners are Masonry Torx Screw
7.5 mm diameter x 40 mm length, part 1CCT1C407.5040, into a pre-drilled 6 mm diameter hole.
6.3. Cable trays on another channel
Channel (as cable tray) can be fixed on top of the main channels using product code SPCF03
(SECT Channel Foot 03), which comprises a channel foot with a M8 fastener and channel nut.
Torx Drive
Undercut
Head with
locking nibs
Hi-lo cutting
threads
Non-
countersunk
into metal to
masonry
Cable tray fixed to concrete sole plates.
SECT channel used as
cable tray, fixed on top of
base channels.