8.
Emergency Power &
Manual Override
How to apply external power if batteries run out
How to use mechanical override key
When the batteries are entirely exhausted, a 9V battery can be used on the emergency
power terminals to allow access. Once the door lock has been reactivated by the 9V
battery, access can be gained via PIN, card/fob or
fi
ngerprint. The batteries in the back of
the lock can then be replaced (see p.7).
Front pad will not
illuminate when
batteries are
exhausted
Open cover
directly beneath
front door handle
Touch terminals
with 9V battery
(place + and - on
either terminal)
Access via
PIN, card/fob
or
fi
ngerprint
Open cover
directly beneath
front door handle
Insert manual
override key and
rotate
Door handle can
now be rotated
for access
NOTE
• Please keep manual override key in a safe, separate place for use in emergencies.