background image

AdditionAl Questions

If you have any additional questions regarding the installation or use of your 
FlexClock, please contact your service provider.

setup 

USE CAUTION

 when making connections to the back board to avoid damage.

Be aware of possible damage due to electrostatic discharge (ESD). ESD is of 

particular concern when working on carpeted surfaces and in dry environments. 

Use a ground strap to minimize ESD concerns.

DO NOT apply power until you are ready to configure the terminal!

If using the optional backup battery, connect backup battery 

BEFORE

 main

power has been supplied!

1.  Connect the earth ground. The earth ground connection is made to the    

 

ground pin on the terminal. Bundle all ground connections into one crimp  

 

lug and attach the lug to the ground pin with an 8-32 nut.

2.  Connect the Ethernet cable to the Ethernet connection socket inside the    

 

terminal casing.

3.  DO NOT apply power until you are ready to configure the terminal!  

 

 

Connect power using the barrel connector.

4.  If using the optional backup battery, locate the backup battery relay.

 

Connect backup battery BEFORE the main power has been connected (step 3).

5.  Make other back board connections as necessary. Use the diagram on the 

 

next page as a reference.

need More?

For a video walk-through visit the following website:

http://www.payrollservers.us/shareddocs/training/source/gt-400/setup.htm

Follow this QR 

code to find the 

video on your 

mobile device.

Summary of Contents for HandPunch GT-400

Page 1: ...FlexClock Hand Geometry Time Clock Setup Guide HandPunch GT 400 ...

Page 2: ...d The earth ground connection is made to the ground pin on the terminal Bundle all ground connections into one crimp lug and attach the lug to the ground pin with an 8 32 nut 2 Connect the Ethernet cable to the Ethernet connection socket inside the terminal casing 3 DO NOT apply power until you are ready to configure the terminal Connect power using the barrel connector 4 If using the optional bac...

Page 3: ... this capability Most small business networks do If your network requires a manual or static configuration your company s IT department should be able to tell you whether you need to set up a Static IP address Usually you do not need to do this If you do you can reach a hidden Network Configuration menu To access this menu press SPACE twice and enter the following password 2663 For firewall admini...

Page 4: ...oubleshooting Troubleshooting Network Connection You can always force the time clock to attempt to contact its server at any time by pressing the 9 key The time clock s ability to transmit depends on your Internet connection If you are having trouble transmitting ensure your Internet connection is up You can unplug the clock s power at any time and plug it back in to force it to acquire a new IP a...

Page 5: ... many applications in which a user is identified from his biometric without any other identification Enrolling Hands To enroll a hand press 1 from the Enrollment Menu First you ll be asked to enter the PIN number for the employee This is the same number used to identify the employee on the timekeeping website Then the employee will be asked to place their hand on the reader a total of three times ...

Page 6: ...everything is correct There should rarely if ever be a need to adjust time cards even if employees worked overnight during the time change If you live in an area that does not observe Daylight Saving Time such as Arizona then the automatic adjustment is disabled by your payroll provider from the website Test Mode On the enrollment menu option 7 Tests allows you to test the hand geometry reader wit...