Silent mode:
Disables the tone sound.
Status indicators:
Located on exterior assembly.
Definitions
Master mode:
The master mode should be entered by entering
[** Master PIN Code #] to program the lock.
Master PIN code:
The master PIN code is used for programming
and for feature settings.
Auto lock:
After successful code entry and the unit unlocks,
it will automatically re-lock after 30 seconds. This
feature is disabled in default setting.
Shutdown time:
The lock will shutdown for a default of 3 minutes
and not allow operation after the wrong code
entry limit (5 times) has been met. When the unit
is in shutdown, the light will flash if you are trying
to use the keypad.
Manual mode:
Auto lock function can be adjusted to manual
mode. In manual mode the lock can be locked by
pressing any key on the keypad for 2 seconds, or
using the thumb turn from the internal unit.
Item
Specifications
Notes
External dimensions
S1:
161mm (L) x 70mm (W) x 25mm (D)
S1K:
137mm (L) x 70mm (W) x 15mm (D)
S1:
196mm (L) x 73mm (W) x 33mm (D)
S1K:
196mm (L) x 73mm (W) x 33mm (D)
AA alkaline battery x 4
(Operation voltage: 4.6~6.0V)
Operation temperature:
-20ºC to 55ºC
Lasts up to one year
(10 times open/close per day)
Internal dimensions
Battery
Hardware specifications
User PIN code:
The user PIN code operates the lock.
Maximum number of user PIN codes is 20.
Away mode:
This feature can be activated or deactivated in
the Schlage Abode App or the lock itself.
Activating away mode will disable all user codes,
except master away mode. If the lock is opened
with a key or manually from inside, the lock will
trigger an alarm. To deactivate the away mode, you
have to enter master code or deactivate in the app.
Fake PIN code:
Random numbers that are added before or after
the user PIN. This prevents the user PIN from
being exposed.
Reset button:
After reset operation, the lock will be restored
to factory default settings, all user credentials
will be deleted. Refer to page 6 for instructions
on how to reset your lock.