background image

Page 3

     

  

User Guide

FRED PA-1® TRAINER

A

rt.

 no.

: 0

-48

-0

293

 Rev

. b

Table of Contents

1

Safety Notes .............................................. 5

1.1

User profiles..........................................................................  5

1.2

Responsibility of the User ...................................................  5

1.3

Intended Use .........................................................................  5

1.4

Contraindication for use ......................................................  5

1.5

Safety-Conscious Operation ...............................................  5

1.6

Maintenance and Cleaning ..................................................  5

1.7

Additional Terms ..................................................................  6

1.7.1

Terms of Warranty .............................................................................  6

1.8

Symbols/Indicators ..............................................................  7

1.8.1

Symbols used in this user guide ........................................................  7

1.8.2

Symbols used on the device ..............................................................  7

1.8.3

Symbols used on the training electrode packaging............................  8

2

Components and Operation .................... 9

2.1

General Information .............................................................  9

2.1.1

Configurations ..................................................................................  10

2.2

Operating and Display Elements ......................................  11

2.2.1

Overview 

FRED PA-1 TRAINER

.....................................................  11

2.2.2

Operating elements..........................................................................  12

3

Initial operation ....................................... 13

3.1

Inserting the batteries ........................................................  13

3.1.1

Switching device On and Off............................................................  14

3.1.2

Device pairing ..................................................................................  14

4

Training ................................................... 15

4.1

Training procedure semi automated AED........................  15

4.2

Training procedure fully automated AED.........................  16

4.3

Accessories and disposables ...........................................  17

4.3.1

Order Information .............................................................................  17

4.3.2

Required accessories.......................................................................  17

4.4

Disposal information..........................................................  18

4.4.1

Battery Disposal...............................................................................  18

4.4.2

Disposal at the end of its useful life..................................................  18

4.5

Troubleshooting .................................................................  19

4.5.1

Troubleshooting ...............................................................................  19

5

Technical Data  ........................................ 20

5.1

System Specifications .......................................................  20

Summary of Contents for 1-134-9901/2.230379

Page 1: ...FRED PA 1 TRAINER Training Device for Automated external defibrillator AED User Guide Art no 0 48 0293 Rev b 0 48 0293 ...

Page 2: ...f all distributors and subsidiaries is provided on our internet site http www schiller ch Sales information can also be obtained from sales schiller ch Manufacturer and responsible for the marking SCHILLER Medical Tel 33 0 388 63 36 00 4 rue Louis Pasteur F 67160 Wissembourg E mail quality schiller fr Web www schiller medical com Article no 0 48 0293 Rev b Issue date 02 07 20 Corresponds to origin...

Page 3: ...s and Operation 9 2 1 General Information 9 2 1 1 Configurations 10 2 2 Operating and Display Elements 11 2 2 1 Overview FRED PA 1 TRAINER 11 2 2 2 Operating elements 12 3 Initial operation 13 3 1 Inserting the batteries 13 3 1 1 Switching device On and Off 14 3 1 2 Device pairing 14 4 Training 15 4 1 Training procedure semi automated AED 15 4 2 Training procedure fully automated AED 16 4 3 Access...

Page 4: ...Page 4 FRED PA 1 TRAINER Art no 0 48 0293 Rev b ...

Page 5: ...s or with the normal defibrillator The FRED PA 1 TRAINER is a simple cost effective simulator of the FRED PA 1 that is designed to be used exclusively for training It must only be used on a mannequin Do not use it as a conventional defibrillator Do not use the device in or near magnetic resonance imaging equipment MRI The device must not be connected to a patient Immediately report any changes tha...

Page 6: ...vice to your dealer or directly to the manufacturer The manufacturer can only be held responsible for the safety reliability and performance of the apparatus and assume the warranty if assembly operations extensions readjustments modifications or repairs are carried out by persons authorised by him spare parts used for assembly operations extensions readjustments modifica tions or repairs are reco...

Page 7: ...ere personal injury or to death For a possibly dangerous situation which could lead to personal injury This symbol is also used to indicate possible damage to property For general safety notes as listed in this section Important or helpful user information CE marking Symbol for the recognition of electrical and electronic equipment The device must be disposed of in a municipally approved collectio...

Page 8: ...t for clinical use Do not store these electrodes with your normal defibrillator Remove the patient s clothes Open the electrode packaging Peel off the protective foil Training Defibrillation electrodes for adult and children with body weight higher than 25 kg Storage temperature for the electrodes Use within one day after opening Keep out of direct sunlight Keep dry Manufacturer information ...

Page 9: ...is done by configuration at produc tion site or distributor Standard package The FRED PA 1 TRAINER standard package includes 1 FRED PA 1 TRAINER 1 SD card with the scenario shock recommended shock recommended shock not recommended 1 set of training electrodes 1 training electrodes cable 4x 1 5V AA LR6 batteries The FRED PA 1 TRAINER doesn t deliver any energy it simply plays through the re suscita...

Page 10: ...ations Configuration Values Device type Automatic semi automatic DA DSA Resuscitation protocol detailed short instructions Patient type Adult Child CPR duration in minutes 1 2 3 Metronome frequency beat min 100 110 120 CPR mode Continuous 30 2 15 2 if patient type is child Audio language List of available language ...

Page 11: ... 2 2 1 Overview FRED PA 1 TRAINER The status LEDs are not active 4 x 1 5 V AA LR6 batteries Training cable with connector to simulate preconnected electrodes Confirmation button that elec trodes are applied and connected Training electrodes only pads to simulate opening and applying the pads on the patient s body Customizable emergency number Shock button ...

Page 12: ...onents and Operation 2 2 Operating and Display Elements Page 12 Art no 0 48 0293 Rev b FRED PA 1 TRAINER 2 2 2 Operating elements 4 x 1 5 V AA LR6 batteries SD card with the scenario On Off switch On Off LED ...

Page 13: ...not be exposed to high temperatures or disposed of with household waste Do not short circuit cut destroy burn or charge a battery Replace the battery if the device indicates a battery problem A defective battery must not be used Insert the battery cover as indicated in the illustration on the left 1 Insert the two stop blocks located at the bottom of the battery cover in the device slots 2 Perform...

Page 14: ...f switch to the left The On Off LED is off 3 Close the cover 3 1 2 Device pairing Off On On Off LED If the cover is closed the device will remind you periodically with an acoustic signal that the device is switched on This is only possible with devices equipped with Bluetooth 1 Open the Schiller Defi training App on your smart phone or tablet PC 2 Select the icon the Device list of Defi training a...

Page 15: ...rmed 9 analysing heart rhythm 10 shock advised 11 do not touch the patient 12 press orange button now if shock button is not pressed within 20 seconds it jumps to 14 13 shock delivered 14 it is now safe to touch the victim 15 advise to do chest compression according to configuration 16 repeat until next instruction the next instruction starts with step 8 After the instruction no shock advised step...

Page 16: ...ain ee Otherwise the instructions are repeated from step 1 After the second repe tition the instructions jump to step 15 8 stand clear of patient heart rhythm analysis will be performed 9 analysing heart rhythm 10 shock advised 11 warning stand clear of patient shock will be delivered 12 3 2 1 13 shock delivered 14 advise to do chest compression according to configuration 15 repeat until next inst...

Page 17: ...e details for all SCHILLER products 4 3 1 Order Information Devices Accessories Disposable 4 3 2 Required accessories User Guide 1 set of training electrodes 1 training electrodes cable 4 x 1 5 V AA LR6 alkaline batteries SD card with shock recommended and then shock not recommended scenario Risk to Persons Equipment Damage Always use SCHILLER replacement parts and disposables or products approved...

Page 18: ...ntain hazardous material and can be recycled like any other piece of electronic equipment In accordance with national law the battery must be dis posed of at an appropriate waste disposal station or returned to SCHILLER According to European legislation this device is considered as electronic waste equipment It can be returned to the distributor or manufacturer where the device will be disposed of...

Page 19: ...1 TRAINER 4 5 Troubleshooting 4 5 1 Troubleshooting Problem Possible causes Remedy The ON OFF LED is off and the device cannot be turned on Battery depleted or inserted with the wrong polarity Device defective Replace the battery Insert the battery correctly Have the device repaired ...

Page 20: ...e Power consumption 6V 4 x 1 5V AA LR6 alkaline batteries max 3 W Environmental conditions Device Operation Storage before use Storage and transport Pollution degree 0 40 C at a relative humidity of 30 to 95 no condensation 0 40 C with the battery inserted Atmospheric pressure 700 to 1060 hPa 0 to 3000 m 20 50 C at a relative humidity of 30 to 95 no condensation Atmospheric pressure 500 to 1060 hP...

Page 21: ...Page 21 Technical Data 5 User Guide System Specifications 5 1 Art no 0 48 0293 Rev b FRED PA 1 TRAINER ...

Reviews: