![schildknecht DATAEAGLE 3323 Installation And Commissioning Manual Download Page 90](http://html1.mh-extra.com/html/schildknecht/dataeagle-3323/dataeagle-3323_installation-and-commissioning-manual_1211962090.webp)
Installation and commissioning DATAEAGLE 3XXX Classic
Chapter 7
– Diagnostic slave
Block 7: Average data rate
Position Meaning
Value
Control Value
Byte 0
Average data rate
slave 1
0 to 255 telegrams/second
Display page (here 7)
Byte 1
Average data rate
slave 2
0 to 255 telegrams/second
Byte 2
Average data rate
slave 3
0 to 255 telegrams/second
0: no function
1: current counter
status slave responses(cleared
every 2.5 seconds)
..
..
Byte 31
7
Feedback from display side
(here 7)
Block 8: Remote control of DATAEAGLE radio slaves
Position Meaning
Value
Control Value
Byte 0
Dummy
127: slave not present
Display page (here 8)
Byte 1
Radio address
of slave1
0 to 99,
127: slave not present
0: no function
1: automatic mode
255: radio slave 1 off
Byte 2
Radio address
of slave2
0 to 99,
127: slave not present
0: no function
1: automatic mode
255: radio slave 1 off
..
Byte 30
Radio address
of slave30
0 to 99,
127: slave not present
0: no function
1: automatic mode
255: radio slave 30 off
Byte 31
8
Feedback from display side
(here 8)
DATAEAGLE 3xxx-A Master tries to connect cyclic all radio slaves which he
knows through the partner address list.
In some applications, parts of the system are switched off intentionally or devices
are moved into a parking position here they cannot reach the radio. This causes
usually a longer reaction time of the wireless link.
To avoid this you can „switch off (control value „255“) the according radio device.
Afterwards the device is not accessed anymore by the so DE3xxx-A Master.
If you want to leave this task to the DE3xxx-A Master switch to automatic mode
(control value „1“).