Okay, so you have a flashing light. Deep 

breath. We’ll get this taken care of shortly.
When the Vidar 2’s front light flashes during  

operation (and the amp mutes), or if it never 

stops flashing after you turn on the amp,  

there’s a problem, or fault. There are three  

kinds of faults:
1. Over-temperature. The heatsinks are too 

hot, and Vidar has shut down to protect its 

output. If the amp is very hot, turn it off, wait 

a while for it to cool down, and try turning 

it on again. Please note that in some very 

hot ambient environments (over 80 degrees 

F), you may need to use an external fan to 

avoid over-temperature faults.
2. Over-current. If Vidar is connected to 

very low-impedance speakers (2 ohms in 

stereo, or 4 ohms in mono), playing very 

loud music can cause an over-current condi-

tion. Simply turn the amp off and on again 

to clear this fault.

FLASHING LIGHTS

Alternately, Vidar may shut off from over-

current if the speaker cables are shorted. To 

troubleshoot this, turn off the amp, discon-

nect the speaker cables from the amp, and 

turn it back on again. If it comes back on, 

there may be a short in your speaker cables 

(or your speakers). Examine your connec-

tions to ensure there are no stray wires or 

shorts. Once those have been fixed, you 

can reconnect the speakers and play music 

again.
3. High DC offset. Vidar is a DC-coupled 

amp. Its microprocessor monitors DC levels 

at the output. However, it may not always 

be able to correct for extremely high DC 

from your source (such as a preamp). To 

clear this fault, turn off the amp, disconnect 

the RCA cables or XLR cable from the amp, 

and turn it back on again. If the amp turns 

on normally, then there may be high DC on 

the output of your source. Have the source 

inspected and repaired.

Summary of Contents for VIDAR 2

Page 1: ...T H E F U L LY M O D E R N O L D S K O O L P O W E R A M P 0222V00000 115VAC 75 ...

Page 2: ...ow how to install audio devices get a qualified professional to help 2 Never use this device near water and clean only with a dry cloth 3 Assure adequate ventilation do not block any ventilation openings or place near heat sources 4 Use only the supplied power cord or suitable replacement Route cords away from traffic areas and protect them from being pinched Unplug the cord from the outlet if the...

Page 3: ...your source with RCA cables right into the input marked R and left into the input marked L 3 Get powered up Connect to a wall socket with the provided AC cord Or you can use any IEC type cord ours isn t special 4 Turn on when it s time for the music Up is on Down is off Pretty simple Feel free to leave the amp on all the time if you d like You can always put it in Standby using the front panel but...

Page 4: ...R cable It s important that the preamp is truly balanced for maximum power output 4 Get powered up Connect to a wall socket with the provided AC cord Or use any IEC type cord ours isn t special 5 Turn on for tunes Up is on Down is off Pretty simple Feel free to leave the amp on all the time if you d like You can always put it in Standby to save power MONO CONNECTION 0222V00000 115VAC 750W 1 3 5 2 ...

Page 5: ... When lit this light indicates Standby mode When flashing it indicates that Vidar 2 is getting everything ready to run 3 When lit this light indicates normal operation When flashing there s a fault See the next section for what to do if it s flashing Vidar 2 takes about 30 seconds to perform self checks when first turned on When coming out of Standby mode it takes about 60 seconds OPERATION 1 3 2 ...

Page 6: ...current condi tion Simply turn the amp off and on again to clear this fault FLASHING LIGHTS Alternately Vidar may shut off from over current if the speaker cables are shorted To troubleshoot this turn off the amp discon nect the speaker cables from the amp and turn it back on again If it comes back on there may be a short in your speaker cables or your speakers Examine your connec tions to ensure ...

Page 7: ...ntact us and obtain an RA email info schiit com Warranty Limitations This warranty shall not apply if a product a is modified or tampered with b is damaged by negligence accident unreasonably use or other causes unrelated to defective materials or workmanship or c has had the serial number altered or removed Any implied warranties including warranties of merchantability and fitness for a particula...

Page 8: ...ing supplies Various Stickers and stuff Infinite Appreciation from the whole Schiit crew in Valencia CA and Corpus Christi TX Even more Thanks from our chassis and PCB guys in California Nevada and Utah This product is in compliance with standards and regulations of the European Community ...

Reviews: