background image

Welcome to a true throwback—a no-

excuses, Class AB, linear supply, heavy-

as-heck power amplifier. But at the same 

time, Vidar 2 has an eye to the future, 

with full microprocessor management 

of all operating conditions, for better 

performance and safety. And we’ve even 

added a super-smart standby mode that 

cuts power consumption to just a watt 

or two, while keeping the amp ready for 

great sound. We hope you really enjoy 

this marriage of old and new! 

INTRODUCTION

The following is required by the roughly 9,542  

government agencies and regulations we have to 

comply with. If you have some common sense, they 

should seem pretty straightforward. In any case, read these 

instructions before proceeding farther, follow all instructions, 

and heed all warnings. Or else! 

1. If you don’t know how to install audio devices, get a  

qualified professional to help.

2. Never use this device near water, and clean only with a  

dry cloth. 

3. Assure adequate ventilation, do not block any ventilation 

openings, or place near heat sources.

4. Use only the supplied power cord or suitable replacement. 

Route cords away from traffic areas and protect them from 

being pinched. Unplug the cord from the outlet if the apparatus 

is unused for a long period of time.

5. To prevent electric shock, do not use the plug with an  

extension cord, receptacle, or outlet unless blades can be  

fully inserted.

6. Refer all servicing to qualified service personnel. Service is 

required when the device has been damaged, including cord or 

plug damage, liquid has been spilled or objects have fallen into 

the device, the device has been exposed to rain or moisture, 

does not operate normally, or has been dropped.

WARNING: TO REDUCE THE RISK OF FIRE OR  

ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE  

TO RAIN OR MOISTURE.

Summary of Contents for VIDAR 2

Page 1: ...T H E F U L LY M O D E R N O L D S K O O L P O W E R A M P 0222V00000 115VAC 75 ...

Page 2: ...ow how to install audio devices get a qualified professional to help 2 Never use this device near water and clean only with a dry cloth 3 Assure adequate ventilation do not block any ventilation openings or place near heat sources 4 Use only the supplied power cord or suitable replacement Route cords away from traffic areas and protect them from being pinched Unplug the cord from the outlet if the...

Page 3: ...your source with RCA cables right into the input marked R and left into the input marked L 3 Get powered up Connect to a wall socket with the provided AC cord Or you can use any IEC type cord ours isn t special 4 Turn on when it s time for the music Up is on Down is off Pretty simple Feel free to leave the amp on all the time if you d like You can always put it in Standby using the front panel but...

Page 4: ...R cable It s important that the preamp is truly balanced for maximum power output 4 Get powered up Connect to a wall socket with the provided AC cord Or use any IEC type cord ours isn t special 5 Turn on for tunes Up is on Down is off Pretty simple Feel free to leave the amp on all the time if you d like You can always put it in Standby to save power MONO CONNECTION 0222V00000 115VAC 750W 1 3 5 2 ...

Page 5: ... When lit this light indicates Standby mode When flashing it indicates that Vidar 2 is getting everything ready to run 3 When lit this light indicates normal operation When flashing there s a fault See the next section for what to do if it s flashing Vidar 2 takes about 30 seconds to perform self checks when first turned on When coming out of Standby mode it takes about 60 seconds OPERATION 1 3 2 ...

Page 6: ...current condi tion Simply turn the amp off and on again to clear this fault FLASHING LIGHTS Alternately Vidar may shut off from over current if the speaker cables are shorted To troubleshoot this turn off the amp discon nect the speaker cables from the amp and turn it back on again If it comes back on there may be a short in your speaker cables or your speakers Examine your connec tions to ensure ...

Page 7: ...ntact us and obtain an RA email info schiit com Warranty Limitations This warranty shall not apply if a product a is modified or tampered with b is damaged by negligence accident unreasonably use or other causes unrelated to defective materials or workmanship or c has had the serial number altered or removed Any implied warranties including warranties of merchantability and fitness for a particula...

Page 8: ...ing supplies Various Stickers and stuff Infinite Appreciation from the whole Schiit crew in Valencia CA and Corpus Christi TX Even more Thanks from our chassis and PCB guys in California Nevada and Utah This product is in compliance with standards and regulations of the European Community ...