Schier solids interceptors are not to be installed in any other manner except as shown.  Consult local 

codes for separate trapping requirements, cleanout locations and additional installation instructions.

6KHHW'HVFULSWLRQV

   

Sheet #1 - Series overview and Warranty information

Sheet #2 - General installation guidelines and Operation/Maintenance guidelines

Sheet #3 - Below Grade installation guidelines (PS-35, PS-50, PS-125, PS-275)

Sheet #4 - Below and Above Grade installation guidelines

Sheet #5 - TeleGlide Riser installation guidelines (PS-35, PS-50, PS-125, PS-275)

Sheet #6 - TeleGlide Riser installation guidelines (PS-15, PS-25)

/HDN6HDO7HVWLQJ

   

'2127$,57(6781,7257(/(*/,'(5,6(56<67(0'RLQJVRPD\UHVXOWLQSURSHUW\GDPDJHSHUVRQDOLQMXU\RUGHDWK

Base Unit:  To perform a leak/seal test on the base unit, cap/plug all plumbing connections, remove the cover, and fill the unit with water just above the

highest connection. Inspect unit and connections for leaks. Check water level at specific time intervals per local code.  

TeleGlide Riser System:  If required by local code, the riser system may be leak/seal tested similar to the base unit. CAUTION: the riser(s) must be supported

before filling with water to keep from tipping over. Once riser system is in place and properly supported, cap/plug all plumbing connections on the main unit,

remove the cover from the top of the riser assembly and fill the unit and riser system with water to finished grade level. Carefully, as the riser(s) will be very

heavy from the weight of the water, inspect all gasket(s) and clamps (if applicable) for any leaks. Check water level at specific time intervals per local code.

/LIHWLPH:DUUDQW\

Effective June 1, 2007 Schier Products Company (“Schier”) represents and warrants that HDPE and PP products (“Products”) will be free from any

and all defects in material and workmanship, including corrosion, during the lifetime of the plumbing system in which the Products were originally

installed and will, at its option, agree to repair, replace, or supply credit to the original purchaser.

This warranty does not cover damage caused by the Products’ normal usage, or wear and tear, nor does it cover damage from naturally occurring

phenomenon, including, but not limited to UV, freeze-related damage, or natural disasters. This warranty does not cover the purchaser’s cost of routine

maintenance including replacement of parts required in routine maintenance.

This warranty does not cover fabricated steel products, or any monitoring equipment. This warranty shall be effective if, and only if, the Products:

* Were installed in accordance with Schier’s notes, specifications and instructions, for installation, operation, and maintenance;

* Were installed in conformance with all applicable building and plumbing codes, and passed all applicable testing methods immediately following installation;

* Have not been subjected to misuse or abuse, whether negligent or intentional;

* Were never modified, repaired, or altered by any individual(s) not authorized by Schier.

This warranty is the purchaser’s sole and exclusive remedy, and acceptance of this exclusive remedy is a condition of the contract for thepurchase of these

Products. In no event shall Schier be liable for any incidental, special, consequential or punitive damages, or for any costs, attorney fees, expenses, losses or

delays claimed to be as a consequence of any damage to, failure of, or defect in any products including, but not limited to, any claims for loss of profi ts,

transportation, removal and installation charges. This warranty is exclusive and in lieu of all other warranties or conditions, written or oral, expressed or implied.

35263(&7256(5,(662/,'6,17(5&(37256

(PS-SERIES)

1RWH

   

Units can be ordered with a removable basket or a removable screen,

depending on your application. Add "-B" for basket, or "-S" for screen to

the end of the model numbers.

'$7(

11/30/11

5(9

01

PS SERIES INSTALLATION, OPERATION 

AND MAINTENANCE GUIDE

6FKLHU3URGXFWV

:RRGHQG5G

(GZDUGVYLOOH.6

7HO

)D[

ZZZVFKLHUSURGXFWVFRP

0DGHLQWKH86$

'(6&5,37,21

':*%<

EAS

6+((7180%(5

1 of 6

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF 

6&+,(5352'8&76

. ANY REPRODUCTION IN 

PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF 

6&+,(5352'8&76

IS PROHIBITED.

35235,(7$5<$1'&21),'(17,$/

(&2

1003

'2&80(17180%(5

057-0650-01

Summary of Contents for PROSPECTOR Series

Page 1: ...eplace or supply credit to the original purchaser This warranty does not cover damage caused by the Products normal usage or wear and tear nor does it cover damage from naturally occurring phenomenon including but not limited to UV freeze related damage or natural disasters This warranty does not cover the purchaser s cost of routine maintenance including replacement of parts required in routine m...

Page 2: ...aced 4 Clean main body of the interceptor Make sure to remove water and fine debris that may have accumulated 5 Replace basket or screen in proper locations 6 Fill unit with water 7 Replace cover s Inspect gasket on underside of cover for wear and tear 8 Properly dispose of collected material 3803 1 5 48 1 Frequency depends on the capacity of the separator and the amount of debris in the wastewate...

Page 3: ...ced 1 Width and length of excavation shall be minimum 12 greater 2 than the tank on all sides Depth of excavation shall be 6 deeper than tank bottom 3 Set the tank in well packed crushed aggregate material 4 approximately 3 4 size rock or sand with no fines Anchor kit is recommended for installations in high water table conditions to 5 prevent float out To be determined by specifying engineer If n...

Page 4: ...7 backfill material approximately 3 4 size rock or sand 2 with no fines 3 Place 6 aggregate base under slab 211 7 216 Connect waste piping to the unit 1 17 5 25 29 5 167 7 21 16758 7 216 36 6 5 6 If concrete slab falls within body of unit reinforce with rebar extending 6 beyond footprint of unit to connect main floor slab When the jobsite requires burying unit flush with floor without using a rise...

Page 5: ...ve been DO NOT cut this new line Once the riser is installed into the main unit this new line will end up at the top of the gasket and will aid in re assembly See Figure 3 IMPORTANT Before the next step 8 Make sure both diffusers are installed inside the main unit at the appropriate locations 1 and check if there needs to be any flow control adjustment on the inlet diffuser Refer to sheet 2 of the...

Page 6: ...ntil it stops about 1 inch See Figure 2 4 Measure the distance from the top edge of the riser down to the finished floor Make sure to account for any future tile work 5 in your measurment See Figure 2 Remove riser from ring Take measurement from step 5 from the BOTTOM of the riser upwards towards the top of the 6 riser Mark a line around the riser and cut with handsaw jig saw or reciprocating saw ...