Prior to Installation
APPLICATIONS
Prima Plus is designed for use on solid fuel, gas and oil burning appliances with continuous
operating temperatures of up to 600°C. With the addition of a lip seal gasket to the joint, Prima
Plus may be adapted for use on condensing gas and oil appliances with positive pressure of up to
200Pa and continuous operating temperatures of up to 200°C. For condensing applications it is
important that any horizontal runs must have a fall of 5°, where headroom makes 5° impossible
the minimum acceptable for warranty purposes is 3°. The design must include drainage
component must be installed within the system to facilitate the safe removal of condensates.
VENTILATION
It is very important that sufficient air for combustion is provided to the room containing the
appliance, to enable correct and efficient working of the system. Reference should be made to
the appliance manufacturer’s instructions and recommendations are also given in the Building
Regulations Document J.
CARBON MONOXIDE ALARMS
The carbon monoxide alarms should comply with BS EN 50291:2001.
Where a new or replacement fixed solid fuel appliance is installed in a dwelling, a carbon
monoxide alarm must be provided in the room where the appliance is located.
Please follow manufacturer’s instructions with regard to siting and fixing or alternatively:-
a) On the ceiling at least 300mm from any wall or if it is located on a wall, as high up as possible
(above any doors and windows), but not within 150mm of the ceiling and
b) between 1m and 3m horizontally from the appliance.
N.B Provision of a carbon monoxide alarm should not be regarded as a substitute for correct
installation and regular servicing.
HANDLING
It is advised that suitable PPE should be used when handling the products.
Delivery to Site and Storage
Components should be carefully transported and off loaded. They should be inspected to
ensure they have not been damaged, and should be stored off the ground and under cover
so that they are protected from accidental damage and the adverse effects of weather.
Particular care and attention should be taken to avoid surface damage to product with the high
temperature painted finish.