Under normal operating conditions and providing the system is installed correctly, it should
last the lifetime of the appliance, which normally is 10 years. ICS carries a 10 year conditional
guarantee. The conditions are that the system is:
•
Correctly sized and installed in accordance with the manufacturer’s instructions, current
Building Regulations and relevant British and European standards.
•
Maintained correctly by a qualified and competent person and maintenance records kept
updated for both appliance and system chimney.
•
Used in combination with an appliance burning only approved fuels in accordance with
Schiedel Chimney Systems and the appliance manufacturer’s instructions.
•
The product registration form must have been filled in by an appropriately qualified installer
(see p.3 for details), and returned to Schiedel Chimney Systems Ltd.
For recommended fuels listings, please refer to the HETAS Guide
www.hetas.co.uk
In the event of a fault developing in the product due to defective materials or faulty manufacture
Schiedel Chimney Systems undertake to replace the product only.
Schiedel Chimney Systems cannot accept liability nor take any responsibility for the installation,
building or redecorating costs or any other consequential losses arising.
If any complaint is found to be a result of faulty installation, non-compliance with or abuse
contrary to these conditions, the cost of site investigation is chargeable.
Product Guarantee
Schiedel Installer Rewards
Exciting news from Schiedel Chimney Systems for Stove and
Chimney Installers! Whenever you register an installation with
our easy to use, online guarantee registration portal, you will
now accrue points based on the number of installations and
installation type.
Once you have reached a minimum of 25 points, you can
begin to redeem them for £25 Love2Shop vouchers.
So head on over to www.SchiedelRewards.co.uk; register your
installations and start earning points!
Notice Plate
Notice Plate for ICS Product
The Notice plate should be marked up in indelible ink and
securely fixed in an unobtrusive but obvious position within
the building such as:
•
Next to the electricity consumer unit.
•
Next to the chimney installation described.
•
Next to the water supply stop-cock.
See example alongside:
The Gables, Greenside, Summerville NE12 9PP
A.N. Other Ltd. First Street, Washington NE38 0AQ
Nestor Martin H13 Wood Burning Stove
Lounge
01/01/16
123456
904 Liner fitted. Chimney swept before installation.
150
150
T600N1WV270012G