11
Installation Instructions
90˚ TEE
This component may be used to connect from a connecting
flue pipe to the vertical system chimney at 90° or the branch
may be used to locate a draft stabiliser. It is installed as per a
standard pipe section.
135˚ TEE - FOR CONDENSING AND NON
CONDENSING
This component may be used in combination with a 45°
elbow to connect from a connecting flue pipe to the vertical
system chimney. It is installed as per a standard pipe section
and provides the least resistance to the flow of the flue gases.
Please refer to the brochure for codes.
93˚ TEE
This component must be used in place of a 90° tee to connect
from a connecting flue pipe to the vertical system chimney
on condensing systems to ensure that condensate can drain
down through the system to a drain point. This component is
installed as per a standard pipe section.
TEE PLUG NON CONDENSING
Used to close off the branch or base of tee. Can also be used
to close end of header. Secured with locking band.
TEE PLUG WITH DRAIN
This component is used on condensing systems and provides
the facility to collect and drain off condensate from the
chimney. It is provided as standard with a 3/4” BSP fitting.
DRAUGHT STABILISER
Used where excessive draught conditions are likely to effect
combustion.
SIDE DRAIN CAP
Used where excessive draught conditions are likely to effect
combustion.