background image

6

Assembly

Measure and note the desired 

location of ISOKERN CELSIUS 

solution. Apply Schiedel ISOKERN 

chimney glue to the pre-prepared 

load bearing reinforced concrete 

slab and place first pumice block. 

Use a spirit level to ensure that the 

block is positioned correctly, then 

the whole installation remains in 

level throughout its length.

Apply glue to the whole surface of 

the block before placing the stove 

recess baseplate. 

Always wipe off excess glue and 

check the level regularly with a 

spirit level.

Apply glue to the whole top 

surface of the module before 

placing the the next block. 

Wipe away any excess glue.

Apply glue all around the edge, 

with the exception of the front 

edge where the appliance will be 

fitted. 

Place first stove recess block.

Apply glue to the module outer 

edge, with the exception of the gap 

for the first ventilation grill. 

The grill should be fitted once the 

blocks have been rendered.

Repeat this process again for each 

of the 7 U shaped stove recess 

blocks.

There are 7 layers to fit in the 

opening for the insert.

1

4

2

5

3

6

Summary of Contents for Isokern Celsius

Page 1: ...on instructions SCHIEDEL INSTALLER REWARDS DEFRA EXEMPT www schiedel com uk DON T FORGET TO REGISTER YOUR INSTALLATIONS AND START EARNING SCHIEDEL INSTALLER REWARDS See inside for more details SAP Issue 1 940003850 October 2020 ...

Page 2: ...driver at delivery and noted on the consignment notes CHIMNEY TYPE AND DISTANCE TO COMBUSTIBLES Minimum distances to combustible material from the chimney is given in the CE designation see page 3 For stoves fireplace inserts and boilers distances to combustible material are also given in the CE designation see page 4 DEFRA EXEMPT Celsius is approved for installation in Smoke Control Areas in the ...

Page 3: ...en established around the insert itself corresponding to 230 cm of air above the insert appliance immediately below the top plate as well as air intake just below the base plate This air circulation is intended to ventilate and heat the room A hearth must be installed in line with Building Regulation guidance Note CE mark and technical specifications are given on page 4 300 mm 300 mm Min 1100 mm t...

Page 4: ...as temperature 242 C PM emission acc to DIN 3 mg m OGC emission 58 mg m NOx emission 82 mg m Minimum distances to combustible material Rear 0mm Front 1 000mm Side 300mm Floor 300mm Fuel Dry wood Schiedel Isokern Celsius installed within an Isokern Pumice frame Use only recommended fuel wood Device approved for log burning only Strictly follow construction and user manual 0036 04 Schiedel Skorstene...

Page 5: ...OKERN Chimney Adhesive is used for the construction of all the Pumice elements within the frame and chimney The mixing instructions are shown on the packaging Apply the glue using the mortar bags provided to achieve a uniform application rate Apply sufficient glue so that the glue is pressed out between the blocks during assembly Excess glue should be removed continuously inside and outside using ...

Page 6: ... Always wipe off excess glue and check the level regularly with a spirit level Apply glue to the whole top surface of the module before placing the the next block Wipe away any excess glue Apply glue all around the edge with the exception of the front edge where the appliance will be fitted Place first stove recess block Apply glue to the module outer edge with the exception of the gap for the fir...

Page 7: ...with the exception of the gap for the 2nd ventilation grill The grill should be fitted once the blocks have been rendered 8 9 Apply glue before fixing the top plate in position 13 Fasten fibre tape once around the underside of the flange of the air outlet Push the long end of the air outlet up through the slit in the top plate on the frame and put 2 layers of fibre tape around the protruding air o...

Page 8: ...MPORTANT Install the plates in position before the bottom vermiculite panels are reassembled Now slide the appliance into position and adjust and fix using the 3 screws at the bottom Putting your hand in through the top hole for the ventilation grill pull the air inlet and flue pipe down into position Glue is not required The steel pipe is sealed into the stove using fire cement 13 14 15 16 18 Put...

Page 9: ...tainless steel pipe shown previously The bottom of the Octagonal adaptor lies flush onto the Pumice top plate The first outer chimney block is glued into place making sure it s square and level Continue adding inner flue blocks and outer casing using lip glue on each joint on both inner and outer blocks 20 19 21 23 To finish off add render with reinforcement mesh being used up to ground floor ceil...

Page 10: ...der to be lip glued onto the last casing 25 Code 4 lead flashing not supplied Capping for render Waterproof render 10mm gap for ventilation under Top Ring At the top of the chimney insert capping fixings into the four corner holes of the casing Fix capping using the bolts provided 28 27 Fit aluminium top ring by pushing the steel prongs into the outside of the inner flue block Make sure it s a tig...

Page 11: ... Guarantee and to start earning points The Schiedel Installation App Download the app today as it offers a number of very useful guides on all aspects of installing an appliance using Schiedel Chimney Systems including Quick and straightforward reference for installers Video breakdowns of each stage of the installation process from connection to the appliance through to termination Highlighting th...

Page 12: ...k A Holton Road Holton Heath Industrial Estate Poole Dorset BH16 6LG Tel 44 0 1202 861650 sales uk schiedel com www schiedel com uk Please note that an updated version of this brochure is always available online https www schiedel com uk brochures ...