Distance requirements:
When choosing a location, consider the illustrations below and the distances to combustible
materials.
When installing against non-combustible material, the requirements of the building regulations
must be followed.
As can be seen from the above drawings and the instructions for the structure of the frame, it is
required that air circulation has been established around the insert itself, corresponding to 230
cm³ of air above the insert appliance immediately below the top plate as well as air intake just
below the base plate. This air circulation is intended to ventilate and heat the room.
A hearth must be installed in line with Building Regulation guidance.
Note: CE mark and technical specifications are given on page 4
300 mm
300 mm
Min. 1100 mm to combustibles
0 mm to combustibles
Min. 300 mm to Ventilation grill
Min. 1100 mm to combustibles
Min. 300 mm
Insert opening
Ventilation
grill
Ventilation grill
Inset opening