When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.
12. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
13. Transport
The kindling splitter can easily be transported with
the help of the three-point attachment on the tractor
unit.
Before transporting the kindling splitter, ensure it is
in the transport position. To do this, lower the riving
knife until it rests on the metal support. Remove the
two L-pins and lower the hydraulic cylinder so it is in
the transport position by pushing both operating han-
dles up or the return bracket down.
When driving, ensure sufficient turning space, e.g.
during reversing, parking and at junctions.
Before transporting the kindling splitter, ensure that
it is properly attached to the tractor unit and that the
drive shaft has been dismantled.
Never transport the kindling splitter when the
shaft drive is connected.
Ensure that the kindling splitter is raised high enough
to avoid obstacles during transport.
14. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
Transport position of the log lifter:
• Using your hand, move the log lifter up until it locks
in position.
Comply with these notices to ensure quick and
safe work.
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer‘s mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE). Extension cables must have
a minimum cross-section of 1.5 mm². Mains fuse pro-
tection is 16 A maximum.